2-90
[
]
2.10.3
AIR CONDITIONER OPERATION PANEL
MAIN POWER SWITCH AND DISPLAY
8
1
2
3
4
5
6
9
10
7
• When the panel is OFF, "OFF" is displayed on (fan
speed/AUTO/OFF) LCD display (9).
• When the panel is OFF, if fan speed selector dial (2) is
operated clockwise, or AUTO control switch (5) is
pressed down, the panel becomes ON and air
conditioner control starts.
Operating fan speed selector dial (2) is operated
clockwise: Operation starts with the fan speed Lo
(manual) (other than the fan speed, the setting is the same as the previous operation)
Pressing down AUTO control switch (5): FULL AUTO operation starts
• If the fan speed selector dial (2) is operated counterclockwise with the fan speed set to Lo, the panel becomes
OFF.
• The air conditioner operation also turns OFF when the starter switch is turned OFF. However, if turned OFF with
this switch, the status of the control panel just before turning OFF is sometimes not recalled when the starter
switch is turned ON again.
FAN SPEED SELECTION AND DISPLAY
In the manual selection, (fan speed/AUTO/OFF) LCD display (9) is like the following.
Fan speed
Lo
(Min.flow)
M1
M2
M3
M4
Hi
(Max. flow)
LCD display
By operating fan speed selector dial (2) in UP (turning clockwise) or DOWN (turning counterclockwise) direction
manually, the AUTO control of fan speed is canceled, and "AUTO" on (fan speed/AUTO/OFF) LCD display (9) is
turned OFF.
COMPRESSOR ON/OFF SWITCHING AND DISPLAY
8
1
2
3
4
5
6
9
10
7
When compressor switch (4) is pressed with "A/C" on
(temperature/A/C) LCD display (8) turned OFF and the
indicator of compressor switch (4) turned OFF, the
compressor turns ON and then "A/C" on (temperature/A/
C) LCD display (8) turns ON and the indicator of
compressor switch (4) turns ON.
If the compressor switch is pressed again, the
compressor turns OFF and "A/C" on (temperature/A/C)
LCD display (8) and the indicator of compressor switch (4) turn OFF.
AUTO CONTROL SWITCHING AND DISPLAY
8
1
2
3
4
5
6
9
10
7
• "AUTO" on (fan speed/AUTO/OFF) LCD display (9)
turns ON only when both the fan speed and the air
outlet are under AUTO control.
• When AUTO control switch (5) is pressed, the fan
speed and the air outlet become under the AUTO
control, and "AUTO" on (fan speed/AUTO/OFF) LCD
display (9) turns ON.
• When the panel is OFF, if AUTO control switch (5) is turned ON, the air conditioner function becomes ON.
However, both the fan speed and the air outlet become AUTO control.
Copyright©2020 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2YY00041ZE03] [0701CsCshWbYs]