42
7.3.4 Span Compensation
【
S.cmp
】
Press key
【
Pause
】
to enter Pause state with red sign ‘
■
’ displaying.
Keep Calibrating Weight [the materials weight in the bucket for Span Calibration] unchanged.
BUCKET-UP: Flip the bucket upward to the limit position.
ARM-DOWN: Put the lift-arm down so that the bucket goes down to the lowest position.
Press key
【
Load
】
to display the blue sign ‘▲’ .
Press key
【
S.cmp
】
to display the interface ‘Span Compensation’:
Lift the lift-arm and bucket with the accelerator at the actual loading operation state and do the
best to keep the accelerator stable.
After the
Magnet Block
passed by the Weighing Segment, display:
Blue sign ‘▼’.
Weighing Result.
Message ‘
【
Ent
】
: Input Cal. Weight’.
Press key
【
Ent
】
to display the interface ‘Input Calibrating Weight’.
After inputting the value of Calibrating Weight, press key
【
Ent
】
to display:
New Span Compensation Coefficient.
Compensation Difference [C.ER = New Span Compensation Coefficient – Old Span
Compensation Coefficient].
AD: AD Value at Weighing Segment.
ACC: Acceleration Value at Weighing Segment [dm/s
2
].