Intra-Sewi KNX TH-Pr

Ambient Climate Sensor with Presence Detector 

Item numbers 70662 (white), 70667 (black)

EN

Installation and Ad justment

Содержание 70662

Страница 1: ...Intra Sewi KNX TH Pr Ambient Climate Sensor with Presence Detector Item numbers 70662 white 70667 black EN Installation and Adjustment...

Страница 2: ......

Страница 3: ...st of all communication objects 13 5 Parameter setting 24 5 1 Behaviour on power failure restoration of power 24 5 2 General settings 24 5 3 Motion detector 24 5 3 1 Master 1 2 3 4 26 5 3 2 Align comm...

Страница 4: ...0 2 Controller setpoint 47 5 9 0 3 Dehumidification and or humidification 48 5 10 Dewpoint measurement 49 5 10 1 Cooling medium temp monitoring 49 5 10 1 1 Threshold value 49 5 10 1 2 Switching outpu...

Страница 5: ...eshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous s...

Страница 6: ...4 Clarification of signs...

Страница 7: ...ach with mixed value calculation The share of internal measurement value and external value can be set as a percentage Bus message whether the values for temperature and air humidity are within the co...

Страница 8: ...tallation approx 31 mm incl clamps Total weight approx 50 g Ambient temperature Operation 20 60 C storage 20 70 C Ambient humidity max 95 RH avoid condensation Operating voltage KNX bus voltage Bus cu...

Страница 9: ...lines to be assembled are free of voltage and take precautions against accidental switching on Do not use the device if it is damaged Take the device or system out of service and secure it against un...

Страница 10: ...s little as possible by external influences Possible sources of interference include Direct sunlight Drafts from windows and doors Draughts from ducts coming from other rooms or the outdoors Warming o...

Страница 11: ...X terminal red black Place the device in the installation opening in the ceiling For this fold the clamps up wards and guide the device through the installation opening with the clamps first Intra Sew...

Страница 12: ...n as shown in the chapter Coverage area of the motion detector Connect the bus line to the KNX terminal red black Clamp the device in the support ring so that the springs on the device snap over the t...

Страница 13: ...onnection The connection is made with the KNX terminal red black to KNX TP Fig 5 Connector socket with 60 mm 42 mm deep 1 Support ring screwed to the socket 2 Springs hold the device firmly on the sup...

Страница 14: ...ve humidity of 95 Avoid condensation The airing lamella must not be closed or covered The device must not be painted over After the bus voltage has been applied the device will enter an initialisation...

Страница 15: ...t 7 Motion sensor Slave Block 1 Blocking Input WC 1 1 DPT_Switch 1 Bit 8 Motion sensor Slave Message Output R CT 1 1 DPT_Switch 1 Bit 9 Motion sensor Slave Cycle reset Input WC 5 1 DPT_Scaling 1 Byte...

Страница 16: ...n delay Input RWC 7 5 DPT_TimePeriodSec 2 Bytes 27 Motion sensor Master 2 Switch off delay Input RWC 7 5 DPT_TimePeriodSec 2 Bytes 28 Motion sensor Master 2 Slave message Input WC 1 1 DPT_Switch 1 Bit...

Страница 17: ...Master 4 Switch on delay Input RWC 7 5 DPT_TimePeriodSec 2 Bytes 49 Motion sensor Master 4 Switch off delay Input RWC 7 5 DPT_TimePeriodSec 2 Bytes 50 Motion sensor Master 4 Slave message Input WC 1 1...

Страница 18: ...from 0 to 1 Input WC 7 5 DPT_TimePeriodSec 2 Bytes 75 Temp thresholdV 2 Switching delay from 1 to 0 Input WC 7 5 DPT_TimePeriodSec 2 Bytes 76 Temp thresholdV 2 Switching output Output R CT 1 1 DPT_Swi...

Страница 19: ...Output WCT 9 1 DPT_Value_Temp 2 Bytes 102 Temp control Setpoint Com fort heat 1 0 Input WC 1 1 DPT_Switch 1 Bit 103 Temp control Setpoint Com fort cooling Input Output WCT 9 1 DPT_Value_Temp 2 Bytes...

Страница 20: ...ol Comfort exten sion status Input Output WCT 1 1 DPT_Switch 1 Bit 124 Temp control Comfort Exten sion time Input WCT 7 5 DPT_TimePeriodSec 2 Bytes 130 Humidity sensor malfunction Output R CT 1 1 DPT_...

Страница 21: ...oldV 3 Abso lute value Input Output WCT 9 7 DPT_Value_Humidity 2 Bytes 151 Humidity thresholdV 3 1 0 Input WC 1 1 DPT_Switch 1 Bit 152 Humidity thresholdV 3 Delay from 0 to 1 Input WC 7 5 DPT_TimePeri...

Страница 22: ...temp Threshold value Output R CT 9 1 DPT_Value_Temp 2 Bytes 177 Cooling medium temp Actual value Input WCT 9 1 DPT_Value_Temp 2 Bytes 178 Cooling medium temp Offset change 1 0 Input WC 1 1 DPT_Switch...

Страница 23: ...put 2 Input WC 5 1 DPT_Scaling 1 Byte 198 Actuating variable comparator 2 Input 3 Input WC 5 1 DPT_Scaling 1 Byte 199 Actuating variable comparator 2 Input 4 Input WC 5 1 DPT_Scaling 1 Byte 200 Actuat...

Страница 24: ...Input WC 1 1 DPT_Switch 1 Bit 224 AND logic 2 1 bit switching out put Output R CT 1 2 DPT_Bool 1 Bit 225 AND logic 2 8 bit output A Output R CT 5 010 DPT_ Value_1_Ucount 1 Bit 2x1 Byte 226 AND logic...

Страница 25: ..._Ucount 1 Bit 2x1 Byte 242 OR logic 2 8 bit output B Output R CT 5 010 DPT_ Value_1_Ucount 1 Bit 2x1 Byte 243 OR logic 2 Block Input WC 1 1 DPT_Switch 1 Bit 244 OR logic 3 1 bit switching out put Outp...

Страница 26: ...is only sent to the bus after a 5 second delay After connecting the operating voltage and after a reset it takes 15 seconds until the sensor is ready for operation Activate the test object if you woul...

Страница 27: ...reset can be found in chapter Align communication between master and slave page 29 Set the sending cycle shorter than the master s switch off delay Set the object type and value for the cycle reset in...

Страница 28: ...tion detection can be used via separate threshold values for switch on and switch off or dependent on daylight The separate threshold values are ideal for controlling the light in rooms which are only...

Страница 29: ...o the measured bright ness value If the room brightness later exceeds this total value because the room is illuminated by daylight the motion control is switched off Settings for all types of motion d...

Страница 30: ...ario call up 2 byte counter without math symbol 2 byte counter with math symbol 2 byte floating point 4 byte counter without math symbol 4 byte counter with math symbol 4 byte floating point Output va...

Страница 31: ...ter than the master s switch off delay Thereby it is ensured that the master does not perform a switch off action while the slave is still de tecting a motion Slave cycle reset The cycle reset for the...

Страница 32: ...e present example the master would immediately switch the light back on 5 4 Temperature Measurement Select whether a malfunction object is to be sent if the sensor is faulty Use Offsets to adjust the...

Страница 33: ...emperature control include the setpoint temperatures for the in dividual modes Objects are used to determine which mode is to be selected A change of mode may be triggered manually or automatically e...

Страница 34: ...is switched off Then define the type of control Heating and or cooling may be controlled in two le vels Switch mode via two 8 Bit objects HVAC Modes three 1 bit objects Mode after reset Comfort Stand...

Страница 35: ...This allows the user to maintain the comfort setpoint value for a longer time e g when having guests The duration of this comfort extensi on period is set After the comfort extension period expires t...

Страница 36: ...e setpoint value may be changed If the comfort setpoint value is used as a basis If the comfort setpoint value is used as a basis the reduction increment of the value is set Eco setpoint Eco mode is u...

Страница 37: ...ion mode General control variables This setting appears for the control types Heating and Cooling only Here you can decide whether to use a common control variable for heating and cooling If the 2nd l...

Страница 38: ...ects is ignored Set the threshold value directly in the application program using parameters or define them via the bus using a communication object Threshold value setting via parameter Set the thres...

Страница 39: ...eshold value in 0 1 C valid until first communication 300 800 200 Object value limit min in 0 1 C 300 800 Object value limit max in 0 1 C 300 800 Type of threshold value change Absolute value Increase...

Страница 40: ...level heating heating is controlled via a PI or a 2 point control Use switching output block No Yes Analysis of the blocking object At value 1 block At value 0 release At value 0 block At value 1 rele...

Страница 41: ...at this point observe ma nufacturer s instructions Now specify what should be sent when the control is blocked Set a value greater 0 OFF to receive a basic heating level e g for floor heating On rele...

Страница 42: ...ange If separate control variables are used select whether the control variable of the 2nd le vel is a 1 bit object on off or an 8 bit object on with percentage off Application Warm water heating Floo...

Страница 43: ...rom the setpoint value which reaches maximum variable value i e the point at which maximum cooling power is activated The reset time shows how quickly the controller responds to deviations from the se...

Страница 44: ...t on off switching of temperatures in the th reshold range If separate control variables are used select whether the control variable of the 2nd le vel is a 1 bit object on off or an 8 bit object on w...

Страница 45: ...ding The minimum and maximum readings can be saved and sent to the bus Use the Reset humidity min max value objects to reset the values to the current readings The values are not retained after a rese...

Страница 46: ...uring initial commissioning a threshold value must be defined which will be valid until the first communication with a new threshold value For units which have already been taken into service the last...

Страница 47: ...Threshold value TV above 1 TV hyst below 0 TV above 0 TV hyst below 1 TV below 1 TV hyst above 0 TV below 0 TV hyst above 1 Delays can be set via objects in seconds No Yes Switching delay from 0 to 1...

Страница 48: ...o set up periodic monitoring using an actuator with this setting On release with 2 seconds release delay Dependent on the Switching output sends setting Switching output sends on change Do not send me...

Страница 49: ...etpoint value can be changed object value limit Enter how the setpoint value will be received from the bus Basically a new value can be received or simply a command to increase or decrease A set setpo...

Страница 50: ...ontroller responds to deviations from the set point value In case of a short reset time the control responds with a fast increase of the control variable In case of a long reset time the control respo...

Страница 51: ...old value dewpoint temperature offset Set in which cases offset received via object is to be retained Please note that the set ting After power supply restoration and programming should not be used fo...

Страница 52: ...bsolute setting 0 1000 50 Threshold value sends never periodically on change on change and periodically At and above change of if sent on change 0 1 C 0 2 C 0 5 C 1 0 C 2 0 C 5 0 C Send cycle if sent...

Страница 53: ...ehaviour of the switching output On block Do not send message send 0 send 1 On release with 2 seconds release delay Dependent on the Switching output sends setting Switching output sends on change Do...

Страница 54: ...teresis 2 RH Absolute humidity hysteresis 2 g kg 5 13 Variable comparator The integrated variable comparators can output maximum minimum and average values Use comfort field No Yes Sending pattern not...

Страница 55: ...Yes Output sends on change of output on change of output and periodically when receiving an input object when receiving an input object and periodically Send cycle if sent periodically 5 s 10 s 30 s 5...

Страница 56: ...tput type is a 1 bit object set the output values for the various conditions AND logic 1 not active active AND logic not active active AND logic 4 not active active OR logic 1 not active active OR log...

Страница 57: ...0 Output value object B if logic 0 0 255 100 360 63 0 Output value object A if block is active 0 255 100 360 63 0 Output value object B if block is active 0 255 100 360 63 0 Output value object A if...

Страница 58: ...nput 4 Logic input 4 inverted Logic input 5 Logic input 5 inverted Logic input 6 Logic input 6 inverted Logic input 7 Logic input 7 inverted Logic input 8 Logic input 8 inverted Logic input 9 Logic in...

Страница 59: ...ctor master 2 output inverted Motion detector master 3 output Motion detector master 3 output inverted Motion detector master 4 output Motion detector master 4 output inverted Switching output 1 Tempe...

Страница 60: ...ontroller inactive Cooling 2 temperature controller active Cooling 2 temperature controller inactive Humidity controller dehumidification 1 active Humidity controller dehumidification 1 inactive Humid...

Страница 61: ......

Страница 62: ...bH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49...

Отзывы: