Knoll IR210 Скачать руководство пользователя страница 1

IR210

 

 

IR210 Infrared Receiver Specifications: 

 

J-box Infrared Receiver  

Specifications

 

Installation Instructions 

v1.2

 

Infrared carrier frequency:   30-60kHz 

 

Indoor reception range:  

20-25 feet (6-8 meters) 

Warning

: To be installed and/or used in accordance with 

appropriate electrical codes and regulations.  

Outdoor reception range: 

Not recommended for outdoor use. 

Nominal reception angle:   50 degrees off axis 

 

Maximum wire length:  

1000’ (300m) or more with larger 
gauge wire 

Introduction:

 Thank you for your purchase of a Knoll IR210 

infrared receiver. This receiver features the ability to pick up a 
remote control infrared signal and relay it on wires to another 

location up to 1000’ (or more). 

Wire requirements:    

3 conductors, minimum 24-gauge 

      

 

 

 

to 200’; 22-gauge up to 500’;  

20-gauge to 1000’ 

 

Power requirements:  

Unregulated 12VDC, 40mA 

Dimensions:    

 

1-3/4" x 4" x 1"  

Features: 

(45mm x 102mm x 26mm)

 

  

 

• 

Inwall junction box design 
available in white, ivory, almond 

and black colors. 

System

 power

on LED

    IR

Receiver

  Blue

talkback

   LED

Requires 12VDC power supply, emitter(s) and IR54, or 

IR55 connection block. 

 

• 

Will relay almost all remote 

types (except some B & O 
models). 

control 

st 

 

 

Warranty

 

 

• 

Can be connected with almost any 
3-conductor wire including cat 5. 

Sugge

Knoll Systems warrants its products sold in the USA and Canada by authorized 
Knoll dealers to be free of defects in materials and workmanship. This warranty 
extends for three full years from the date of purchase by the original consumer. 
Any products returned to Knoll Systems and found to be defective by Knoll 
Systems within the warranty period will be repaired or replaced at Knoll Systems 
option, at no charge. Knoll Systems will not be responsible for the actual cost of 
installation or removal of the product, nor for any incidental or consequential 
damages. Some states do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation may not apply to you.  This 
warranty gives you specific legal rights.  You may have additional legal rights 
that vary from state-to-state. 

• 

Requires very little power. 
using PS1202 12 VDC (200 mA
for up to 5 IR210s.  

• 

Up to 10 IR10’s, IR210’s and other 
compatible models can be 

connected in a single system. 

• 

Connects with a three wire 

connector or RJ45 via cat 5 wire 

 
 

 

 

Installation Tips 

 

 

 

1. Follow all local electrical & building code requirements. 

 

 

 

2. The IR210 is usually wall mounted. It does not normally 
require a junction box. For easy installation and to ensure 

reliability, it is suggested that a PS1202 (200 mA) or PS1205 
(500 mA) 12 VDC unregulated power supply, IR31 (single) or 

IR34 (dual) emitters and one of the following: IR54 (decora 

 

Knoll Systems www.knollsystems.com   

145 Tyee Drive Point Roberts, WA 98281 

12140 Horseshoe Way, Richmond BC V7A 4V5 
Telephone: (604) 272-4555, Fax: (604) 272-5595 

Made in Canada   Knoll Systems All Rights Reserved 