These instructions should be read carefully and retained after installation by the end user for future reference 
and maintenance.
These instructions should be used to aid installation of the following product:
VFR7EM

GENERAL INSTRUCTIONS

SAFETY

INSTALLATION

•  This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current 

Building Regulations. If in any doubt, consult a qualified electrician

• Please isolate mains prior to installation or maintenance
•  Check the total load on the circuit (including when this accessory is fitted) does not exceed the rating of the circuit cable, 

fuse or circuit breaker

• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
• Allow 50mm above and around the product for air dissipation (do not cover with insulation)
• Do not overload this accessory or subject it to conditions outside its rating
• This product is Class II double insulated 
• This product is IP20 rated

Note

 - this product is specifically manufactured to convert the Knightsbridge LED Downlights VFRCOBxx, VFR8xxx and 

VFRIC8xx to 3-hour emergency fittings. No guarantee can be given that it is compatible with any other manufacturer’s 
fittings. To use with the VFRIC8xx range, an additional pair of connector leads ICEMC is required.

INSTRUCTIONS 

 VFR7EM 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product: 

VFR7EM 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this accessory is fitted) does not exceed the rating 

of the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

Allow 50mm above and around the product for air dissipation (do not cover with insulation) 

 

Do not overload this accessory or subject it to conditions outside its rating 

 

This product is Class II double insulated  

 

This product is IP20 rated 

INSTALLATION 
Note -

 this product is specifically manufactured to convert the Knightsbridge LED Downlights VFRCOBxx, 

VFR8xxx and VFRIC8xx to 3-hour emergency fittings. No guarantee can be given that it is compatible with any 

other manufacturer's fittings. To use with the VFRIC8xx range, an additional pair of connector leads ICEMC is 

required. 

 

Provide power to the required point of installation  

 

Cut a suitable hole in the mounting surface as per the cut-out details of the downlight to be used, 

ensuring not to infringe with any joists, gas/ water pipes or electrical cables. This emergency kit 

requires a minimum 60mm cut-out  

 

Wire the Permanent Live and Neutral to the VFR7EM Emergency Kit (see Fig. 1) 

 

Fig. 1  

•  Provide power to the required point of installation 
•  Cut a suitable hole in the mounting surface as per the cut-out details of the downlight to be used, ensuring not to 

infringe with any joists, gas/water pipes or electrical cables. This emergency kit requires a minimum 60mm cut-out 

•  Wire the Permanent Live and Neutral to the VFR7EM Emergency Kit (see Fig. 1)

Fig. 1