KNIGHT SMART CART OPERATION MANUAL
SECTION 2
INSTALLATION
8
Step 1: Control Handle Set-up
There are (2) two control handle configurations. This section discusses the correct setup of each of these.
1a) Analog Lever Handle setup
1b) Discrete Up / Down Handle setup
Step 1a) Analog Lever Handle Setup:
1) The Analog Lever Handle comes standard with the system. (Refer to Figure 2-3)
2) If a new Analog Lever Handle has to be calibrated for the system, please follow these steps:
i. Attached the 8-pin cable to the new handle and mount it to the cart’s handle post.
ii. Remove the Control Box’s cover.
iii. Press the Blue button located on the left-hand side of the battery. It will light up.
iv. Press the Analog Lever fully to the Right.
v. Press the Analog Lever fully to the Left.
vi. Allow the Analog Lever to “rest” in its natural home position without moving it.
vii. The Blue light will flash indicating that the new Analog Lever Handle has been
calibrated.
Figure 2-3
Step 1b) Discrete Up / Down Handle setup:
1) This handle is not standard with a new system. If one is required, please contact Knight personnel
for instructions on how to calibrate the digital Up / Down handle.
8-pin Cable
Analog
Thumb
Lever