29
ProLine P16800
4.2 DIP Switches
The input and output functions of the P16800 can be individually adjusted via DIP switches on the
product. Which functions go with which DIP switch positions is indicated on the nameplate.
NOTICE!
Do not change the measuring range during operation.
01.
Set the DIP switches according to the desired function.
02.
Following configuration, check the speed signal doubler to make sure it is functioning correctly.
DIP switch at input
Overview of the functions of the DIP switches at input:
• DIP switch input 1 and input 2 (optional)
◦
Choice of current or voltage input
◦
Choice between 1:1 pulse transmission or frequency division 2:1
(optional ex works: 4:1 or 8:1)
DIP 1
DIP 2
Input value
Notes
Factory setting
On
(ON)
On
Low 0 V
High U
S
Voltage input,
pulse transmission 1:1,
no frequency division
On
Off
(OFF)
Low 6/7 mA
High 14/20 mA
Current input,
pulse transmission 1:1,
no frequency division
Off
On
Low 0 V
High U
S
Voltage input,
frequency division 2:1
(optional ex works: 4:1 or 8:1)
Off
Off
Low 6/7 mA
High 14/20 mA
Current input,
frequency division 2:1
(optional ex works: 4:1 or 8:1)
Содержание ProLine P16800
Страница 28: ...ProLine P16800 28 Shielding via the inner shield of the speed sensor enclosure ...
Страница 49: ...ProLine P16800 49 Notes ...
Страница 50: ...ProLine P16800 50 ...
Страница 51: ...ProLine P16800 51 ...