ProLine P16800
23
Removing the P16800 from the wall-mount adapter
To remove the P16800 in the wall-mount adapter, the M6 screws must first be loosened. Slightly bend
up one side of the wall-mount adapter to separate it from the product.
See also
3.2 Terminal Assignments
Terminal
Label
Input/
output
Channel Function
1.1
V
S
Output
2
Voltage supply
1.2
U
B
Output
2
Voltage supply (output driver)
If terminal U
B
is open, the output driver is supplied via V
S
and an
internal DC/DC converter.
1.3
Out
Output
2
Output signal (current or voltage)
1.4
SW
Output
2
Switching output, open in the case of a detected error.
2.1
GND
Output
1
Ground (reference potential)
2.2
Screen
Output
1
Shield
2.3
Screen
Output
2
Shield
2.4
GND
Output
2
Weight
3.1
V
S
Output
1
Voltage supply
3.2
U
B
Output
1
Voltage supply (output driver)
If terminal U
B
is open, the output driver is supplied via V
S
and an
internal DC/DC converter.
3.3
Out
Output
1
Output signal (current or voltage);
With product variant with DOT function (P16840, direction of rota-
tion/direction of travel detection): Result of the phase comparison.
3.4
SW
Output
1
Switching output, open in the case of a detected error.
4.1
U
S
Input
1
Voltage supply speed sensor
4.2
I
Input
1
Signal current from speed sensor
4.3
U
Input
1
Signal voltage from speed sensor
4.4
GND
Input
1
Speed sensor ground
5.1
GND
Input
2
Speed sensor ground
5.2
Screen
Input
2
Shield
5.3
Screen
Input
1
Shield
5.4
GND
Input
1
Speed sensor ground
6.1
U
S
Input
2
Voltage supply speed sensor
6.2
I
Input
2
Signal current from speed sensor
6.3
U
Input
2
Signal voltage from speed sensor
6.4
GND
Input
2
Speed sensor ground