Diaphragm liquid pump NF 2.35
Operation
KNF Flodos AG BA_NF2-35_EN_02_164912
Translation of original Operating and Installation Instructions
13
7. Operation
➔
Only operate the pumps under the operating parameters and
conditions permitted in these instructions (see especially Chap-
ter 4, Technical data).
➔
Make sure that the pumps are being used properly (see Chap-
ter 2.1).
➔
Avoid improper use of the pumps (see Chapter 2.2).
➔
Observe the safety precautions (see Chapter 3).
➔
The pumps are components that are intended to be incorpo-
rated into another machine. Before putting them into service it
must be established that the machinery or systems in which
they are installed meet the relevant regulations.
CAUTION
Risk of burning
The motor heats up.
➔
Avoid contact with the pump motor.
➔
Avoid contact with flammable materials.
One means of preventing excessive pressure and the
inherent dangers thereof is to place a bypass line with a
pressure relief valve between the pressure and suction
sides of the pump. For further information, contact your
KNF technical adviser (for contact details, see last page).
➔
If the pump stops running, restore the system to normal at-
mospheric pressure.
For pumps with thermal switch or electronic overload protection:
WARNING
Personal injury or damage to pumps or the con-
nected system as a result of automatic start-up
If the pump overheats and pump operation is
stopped by the thermal switch / electronics, the pump
will restart automatically as soon as it has had time to
cool down.
➔
Take steps to ensure that this cannot produce a
hazardous situation.
Replace filter (accessory) if dirty.
Check the pump regularly for external damage or leaks.
Switching the pumps on and off
The motor speed of the pump, and thus the flow rate, is adjustable
and can also be regulated to some extent
.
Pump standstill
Filter
Check the pump
Setting and regulating motor
speed