6.  Transportation 

 

 

CAUTION 

 Personal injury and/or damage to property because 

of false or improper transportation of the pump 

 

Due to false or improper transportation the pump can 
fall down, become damaged and injure people. 

 

  If necessary, use suitable aids (eyebolt, harness, 

lifting device, etc.). 

  If necessary, wear proper personal protective 

equipment (e.g. safety gloves, safety shoes). 

 

 

CAUTION 

 Danger of injury due to sharp edges on the package 

 

When handling or opening the package there is the 
possibility of injury by cutting at sharp edges. 

 

  If necessary, wear proper personal protective 

equipment (e.g. safety gloves). 

 

  Carry the pump in the original packaging up to its place of in-

stallation. 

  Retain the original packaging of the pump (e.g. for later stor-

age). 

  Check the pump for transport damages after receipt. 

  Document occurred transport damages in writing and with pic-

tures. 

  If necessary, remove the transport safety devices before com-

missioning the pump. 

 

Parameter 

Parameter 

Value 

Storage temperature 

+ 5°C to + 40°C 

Transport temperature 

- 10°C to + 60°C 

Permiss. humidity (non-con-

densing) 

30% to 85% 

 

Tab. 8 

 

Содержание N86.16 Series

Страница 1: ...LATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH DIAPHRAGM VACUUM PUMPS AND COMPRESSORS Note Before operating the pump and the accessories please read the operating instructions and...

Страница 2: ...nction 11 6 Transportation 12 7 Installation and connection 13 8 Operation 17 9 Servicing 19 10 Troubleshooting 24 11 Spare parts and accessories 26 12 Returns 27 KNF Neuberger GmbH Alter Weg 3 79112...

Страница 3: ...Warning WARNING A danger is located here Possible consequences of a failure to observe the warning are specified here The signal word e g Warning indicates the danger level Measures for avoiding the d...

Страница 4: ...rain splash hose and drip water as well as other pollutions The gas tightness of the connections between the application pipes and the pump or the pump connection must be checked regularly with leaky...

Страница 5: ...liquids aerosol biological and microbiological substances fuel explosive and combustible materials fibers oxidizing agent foodstuffs The pumps are not suitable for use with aggressive media Other pum...

Страница 6: ...Make sure that the personnel has read and understood the Operat ing and Installation Instructions and in particular the Safety chap ter Observe the accident prevention and safety regulations when per...

Страница 7: ...interna tional regulations This especially applies to parts contaminated with toxic substances For the purposes of the Machinery Directive 2006 42 EC pumps are partly completed machinery and are there...

Страница 8: ...nce free But KNF recommends checking the pump regularly with regard to conspicuous changes in noise and vibrations Only have repairs to the pumps carried out by the KNF Customer Service responsible Ho...

Страница 9: ...ssure l min 6 0 Tab 3 Liters in standard state 1013 mbar Pneumatic Connections Pump type Value N86AT 16E Thread size G 1 8 N86ST 16E Thread size G 1 8 Tab 4 Electrical data Parameter Value Electrical...

Страница 10: ...s See Fig 3 Chapter 7 1 Maximum permissible ambient relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 at 40 C Max altitude of site m above sea level 2000 Gas tightness of pump...

Страница 11: ...lastic diaphragm 4 is moved up and down by the eccentric 5 and the connection rod 6 In the downward stroke it aspirates the gas to be transferred via the inlet valve 2 In the upward stroke the diaphra...

Страница 12: ...oes CAUTION Danger of injury due to sharp edges on the package When handling or opening the package there is the possibility of injury by cutting at sharp edges If necessary wear proper personal prote...

Страница 13: ...he insulation resistance with a suitable meas uring instrument megaohmmeter with 500V DC test voltage Rmin 5 M depending on the type of heating element and the storage conditions e g high humidity If...

Страница 14: ...t the installation location is accessible for maintenance and service Make sure that reaching into the fan is avoided The IP protection class of the pump motor is indicated on the type plate Install t...

Страница 15: ...t of the pump see pump s type plate It is recommended that an additional Emergency Stop switch is installed The pump must be installed so that contact with live parts is impossible Fasten the connecti...

Страница 16: ...the first shut off valve If the pump s used as a vacuum pump safely discharge the pump exhaust at the pump s pneumatic outlet KNF recommends mechanically disengaging the pump from the piping system Th...

Страница 17: ...e pumps are not used improperly see Chapter 2 2 Observe the safety precautions see Chapter 3 The pumps are intended for installation Before putting them into service it must be established that machin...

Страница 18: ...pump at a standstill open pressure and suction lines to normal atmospheric pressure The pump may not start up against pressure or vacuum during switch on This also applies in operating following a br...

Страница 19: ...ngerous and environmentally hazardous me dia KNF recommends flushing the pump at atmospheric pressure for a few minutes prior to switch off if necessary for safety rea sons with an inert gas to extend...

Страница 20: ...ts 1 O ring 1 Tab 10 according to spare parts list Chapter 11 1 Tools Material Fork wrench or socket wrench 5 5 mm Pin wrench for two hole nuts pin diameter 4 mm available as wrench for retainer plate...

Страница 21: ...ump head exploded drawing The following item numbers refer to Fig 4 Fig 6 unless speci fied otherwise 1 Carrier 2 Wave diaphragm 3 Intermediate plate 4 Head plate 5 Disk spring 6 Nut 7 Retainer plate...

Страница 22: ...wrench for retainer plate While doing so hold the connecting rod extension 9 in place with holding tool Take care to ensure that the washer 12 does not slip under the diaphragm support 8 2 Remove wav...

Страница 23: ...felt tip pen marking 2 Place disk springs 5 For position see Fig 6 3 Put the nuts 6 in place and tighten them diagonally until each of them lies level on the top spring washer realign the pump head Fr...

Страница 24: ...fuse and switch on if necessary Connections or lines are blocked Check connections and lines Remove blockage External valve is closed or filter is clogged Check external valves and filters Condensate...

Страница 25: ...ues Eliminate throttling e g valve if necessary Use lines or connection parts with larger cross section if necessary Leaks occur at connections lines or pump head Eliminate leaks Connections or lines...

Страница 26: ...260 121531 04 20 11 Spare parts and accessories 11 1 Spare part set A spare part set consists of Spare part Position number Quantity Valve plate 11 1 Wave diaphragm 2 1 O ring 10 1 Tab 14 Spare part s...

Страница 27: ...Prerequisite for repairing a pump by KNF is a completed Decon tamination Form This is made available on the KNF website as a download To find the form select your country on the overview page www knf...

Страница 28: ...KNF worldwide Find your local KNF partner on www knf com...

Отзывы: