Use
Diaphragm pump N85, N86
4
Translation of original Operating and Installation Instructions, english, KNF 121258-121528 01/20
2. Use
2.1. Proper use
The pumps are exclusively intended for transferring gases and
vapors.
Owner’s responsibility
Only install and operate the pumps under the operating parameters
and conditions described in Chapter 4. Technical Data.
Only complete pumps may be taken into service.
Make sure that the installation location is dry and the pump is pro-
tected against rain, splash, hose and drip water as well as other
pollutions.
The gas-tightness of the connections between the application
pipes and the pump (or the pump connection) must be checked
regularly; with leaky connections, there is a danger that hazardous
gases or vapors may escape from the pump system.
Before using a medium, check whether the medium can be trans-
ferred danger-free in the specific application case.
Before using a medium, check the compatibility of the materials of
the pump head, diaphragm and valves with the medium.
Only transfer gases which remain stable under the pressures and
temperatures occurring in the pump.
2.2. Improper use
The pumps may not be operated in an explosive atmosphere.
The pumps are not suitable for transferring;
dusts
liquids
aerosol
biological and microbiological substances
fuel
explosive and combustible materials
fibers
oxidizing agent
foodstuffs.
The pumps are not suitable for use with aggressive media. Other
pumps in the KNF product line are designed for use with aggres-
sive media. Please contact us for more information.
The pumps must not be used to create vacuum and overpressure
simultaneously.
An overpressure must not be applied to the suction side of the
pump.
Operating parameter and
conditions
Requirements for