Electric motors Size 63 - 225 ATEX / IECEx
Technical data
22
2021-05-31
Section
Designation
Significance
Explosion protection symbol
Marking for protection from explosions
II
Device group
Device group II. The motor can be used in potentially
explosive areas except in mining.
2
Category
For application in Zone 1 and Zone 21
G
D
Explosive atmosphere
… cause by gas.
… cause by dust.
Ex
Standard
Standard on explosion protection
d / db
e / eb
tb
Ignition protection type
Pressurised enclosure.
Increased safety.
Protection by housing
IIC
IIB
IIIC
IIIB
Explosion group
Dust group
Maximum experimental safe gap (MESG)
Type and shape
T1
– T6
Temperature class
maximum surface temperature present
T1 (450 °C)
– T6 (85 °C)
Gb
Db
EPL
equipment protection level
3. 12 /KN 2006-SM /nL---------- Abschnitts ende ---------- @ 8\ mod_1141997892953_0.doc @ 75471
3.13 /KN2006- Proj ekte/H erfor der El ektromotoren- Wer ke/T ec hnisc he D aten/HIN WEIS - Weitere Sc hilder @ 59\mod_1203071538887_1.doc @ 1034103
Pos : 4.1 /KN2006- SM/nL.......... Seitenumbr uc h .......... @ 8\mod_1141998334703_0.doc @ 75489
NOTE!
There may be further signs on the machine with various pieces of information.