Diaphragm pump N680 EX
Transport
Translation of Original Operation and Installation Instruction, english, KNF 325438 02/22
19
Transporting with lifting eyebolt
1. Loosen the M12 screw (1).
1
M12 screw
Fig.3 Loosen the M12 screw (pump illustrated as an example)
2. Screw the transport eyebolt (2) hand-tight into the threaded hole.
The transport eyebolt (2) is available as an accessory (see
2
Transport eyebolt
Fig.4 Transport eyebolt (depicted pump as an example)
3. Lift the pump out of the packaging with the aid of lifting gear.
4. Lower the pump carefully at the installation location.
5. Remove the transport eyebolt (2).
6. Screw the M12 screw (1) back into the thread.