Technical Data
Vacuum Pumps N 920 APE-W and N 920 APDC-B
10
Translation of original Operating and Installation Instructions, english, KNF 121690-121708 09/19
N 920 APDC-B
Parameter
Value
Motor type
Brushless DC motor
Voltage [V]
24 V
Max. operating current [A]
4.2
(starting current, momentary
200 ms: 7A)
Power consumption pump [W]
100
Maximum permitted mains
voltage fluctuations
+/- 10%
Protection class Motor
IP 00
Tab. 7
The pump is supplied by a universal power supply with inte-
grated overload protection. It is protected against overheating
by a temperature sensor on the motor board and equipped with
overcurrent protection.
If one of these safety functions is triggered, the pump will be
shut down and must be manually reset, as follows:
➔
Separate pump from electrical power supply
➔
Remove the cause(s) of the fault before restarting.
Weight
Pump type
Value
N 920 APE-W
10.0 kg
N 920 APDC-B
8.5 kg
Tab. 8
Other parameters
Parameter
Value
Permissible ambient tempera-
ture
+ 10°C bis + 40°C
Permissible media tempera-
ture
+ 5°C bis + 40°C
Dimensions L x H x W [mm]:
N 920 APE-W
N 920 APDC-B
324 x 182 x 127
292 x 161 x 119
Maximum permissible ambient
relative humidity
80% for temperatures up to
31°C, decreasing linearly to
50% at 40°C.
Max. altitude of site:
[m above sea level]
2000
Tab. 9