Operating Instructions LIQUIPORT EN
Safety
KNF Flodos | BA_LIQUIPORT_EN_11_153820.docx | Translation of original operating instructions, English
11
2.5 Product-specific dangers
This chapter describes residual risks that have been identified in a risk
assessment. Safety precautions and warnings in this chapter and in
other chapters in the Operating Instructions must be observed in order
to avoid dangerous situations.
DANGER
Danger of injuries and property damage caused by leaks in con-
nections and the pump head
Poisoning and caustic burns, or undesirable reactions caused by es-
caping hazardous materials
-
Maintain the torque of connections (see hydraulic connec-
tions)
-
Check tightening torque of head screws regularly
-
Only use pump if it is in perfect working order
-
Operate pump in accordance with the technical data
DANGER
Danger of injuries and property damage caused by medium es-
caping from the discharge outlet
Poisoning and caustic burns, or undesirable reactions caused by es-
caping hazardous materials
-
Place the pump in a suitable collecting vessel
-
Never close the discharge outlet
-
If medium escapes from the pump's discharge outlet, stop
using the pump and contact your KNF dealer
DANGER
Risk of fire from escaping flammable media
Escaping or leaking flammable media can produce a combustible en-
vironment.
-
Take fire protection precautions that are appropriate for the
transferred media
-
Keep ignition sources away
-
Keep suitable extinguishers accessible
-
Use means of fire detection
WARNING
Danger of serious injuries or property damage caused by escap-
ing media in the event of overpressure on the suction side
Excessive pressure on the suction side will result in uncontrolled es-
cape of fluid, even if the pump is not operating
-
Avoid overpressure on the suction side
Содержание LIQUIPORT 1.100