Knauer HPLC IFU 2.1 Скачать руководство пользователя страница 4

Overview and Connectors

5

IFU 2.1 User Manual V6805, Version 2.0

Overview and Connectors

Front View of the Device

Computer defect

No electrical isolation is provided for the Interface Box. Voltages above 10 V 
could damage connected computers.

Take protective measures.

Use the device according to the specifications.

 

LED

LEDs indicate the device's condition. The green LED „Power“ shows that the 
device has successfully been connected to a computer. The yellow LED „Busy“ 
shortly lights up during calibration or after receiving a signal from the control 
software. Calibration is done when starting a device or a run. „Busy“ perma-
nently lights up if the control software checks on the device's status regularly, 
e. g. every second.

Legend

AN.IN (data signal input)

AN.OUT (output of analog control signal)

DIG.IN (trigger input)

DIG.OUT and autozero

Channel 1

Fig. 2 Front view of interface box IFU 2.1

1

2

3

4

5

Содержание HPLC IFU 2.1

Страница 1: ...Interface Box IFU 2 1 User Manual V6805 HPLC...

Страница 2: ...verview and Connectors 5 Front View of the Device 5 LED 5 Analog Inputs AN IN 6 Analog Outputs AN OUT 6 Digital Inputs DIG IN 6 Digital Outputs DIG OUT 7 Installation 7 Power Supply 7 Connecting the I...

Страница 3: ...ther informations comes included with the manual of the device The interface box is no standalone device which means that software control is strictly required e g KNAUER ChromGate or KNAUER ClarityCh...

Страница 4: ...tion The green LED Power shows that the device has successfully been connected to a computer The yellow LED Busy shortly lights up during calibration or after receiving a signal from the control softw...

Страница 5: ...The outputs can be programmed inde pendently of each other This e g refers to the control of pumps in a high pres sure gradient system Digital Inputs DIG IN These four inputs are trigger inputs recei...

Страница 6: ...easures Use the device according to the specifications Connecting the Interface Box to a Computer To establish a connection between the interface box and the computer you take the USB cable from the a...

Страница 7: ...user manual of the device Please pay attention to the allowed maximum voltage Otherwise the device can get damaged KNAUER can not be held reliable in this case The required components of the remote co...

Страница 8: ...g input of a channel can not be used at the same time except the analog input is used for autozero of a detector Process Figure 1 Guide the blunt side of the depres sor tool into the square opening of...

Страница 9: ...10 Technical Data IFU 2 1 User Manual V6805 Version 2 0 Technical Data Fig 5 Exemplary cable plan Power connection via USB 2 0 5 V max 500 mA Dimensions 105 x 26 x 161 5 mm W H D Weight 0 35 kg...

Страница 10: ...shall expire in the event that any unauthorized changes are made to the device This warranty also excludes the following accidental or willful damage damage or errors caused by third parties that are...

Страница 11: ...version 2 0 2016 04 20 Printed in Germany on environmentally friendly paper from sustainable forests See up to date manuals online www knauer net downloads HPLC SMB Osmometry KNAUER Wissenschaftliche...

Отзывы: