Intended Use

IFU 2.1 User Manual V6805, Version 2.0

Intended Use

Interface box IFU 2.1 solely supports connections with USB 2.0 

1

.

 

The interface box IFU 2.1 has 4 channels for data recording and device control 
for devices that are not supported by KNAUER software. This includes data 
recording from detectors via analog inputs, flow rate control for HPLC pumps 
via analog outputs or switching of valves via digital outputs. The only require-
ment is that the device supports these tasks. Further informations comes 
included with the manual of the device.

The interface box is no standalone device, which means that software control is 
strictly required (e. g. KNAUER ChromGate or KNAUER ClarityChrom). 

Note: 

Which interface box functions are supported by the control software can 

bef found in the software manual. The software manual also includes informa-
tion on configuring and programming the interface box for the Smartline Man-
ager 5000. 

Scope of Delivery

Contents of the interface box accessories kit:

4 x remote connector, 9-pin

1 x depressor tool

1 x USB cable (mini B/standard A)

1 x cable with wired ends

3 x flat band cable, 10-pin

Fig. 1 Interface box IFU 2.1 with USB connector.

1

Содержание HPLC IFU 2.1

Страница 1: ...Interface Box IFU 2 1 User Manual V6805 HPLC...

Страница 2: ...verview and Connectors 5 Front View of the Device 5 LED 5 Analog Inputs AN IN 6 Analog Outputs AN OUT 6 Digital Inputs DIG IN 6 Digital Outputs DIG OUT 7 Installation 7 Power Supply 7 Connecting the I...

Страница 3: ...ther informations comes included with the manual of the device The interface box is no standalone device which means that software control is strictly required e g KNAUER ChromGate or KNAUER ClarityCh...

Страница 4: ...tion The green LED Power shows that the device has successfully been connected to a computer The yellow LED Busy shortly lights up during calibration or after receiving a signal from the control softw...

Страница 5: ...The outputs can be programmed inde pendently of each other This e g refers to the control of pumps in a high pres sure gradient system Digital Inputs DIG IN These four inputs are trigger inputs recei...

Страница 6: ...easures Use the device according to the specifications Connecting the Interface Box to a Computer To establish a connection between the interface box and the computer you take the USB cable from the a...

Страница 7: ...user manual of the device Please pay attention to the allowed maximum voltage Otherwise the device can get damaged KNAUER can not be held reliable in this case The required components of the remote co...

Страница 8: ...g input of a channel can not be used at the same time except the analog input is used for autozero of a detector Process Figure 1 Guide the blunt side of the depres sor tool into the square opening of...

Страница 9: ...10 Technical Data IFU 2 1 User Manual V6805 Version 2 0 Technical Data Fig 5 Exemplary cable plan Power connection via USB 2 0 5 V max 500 mA Dimensions 105 x 26 x 161 5 mm W H D Weight 0 35 kg...

Страница 10: ...shall expire in the event that any unauthorized changes are made to the device This warranty also excludes the following accidental or willful damage damage or errors caused by third parties that are...

Страница 11: ...version 2 0 2016 04 20 Printed in Germany on environmentally friendly paper from sustainable forests See up to date manuals online www knauer net downloads HPLC SMB Osmometry KNAUER Wissenschaftliche...

Отзывы: