15
Decommissioning, transport and storage
If you plan to take the freshness cooler
out of operation for a longer period of
time proceed as described below:
• Remove all goods from the freshness
cooler.
• Turn off the freshness cooler.
• Wait until the temperature of the
freshness cooler has adjusted to the
room temperature.
• Clean all parts of the cooler as descri-
bed in the „Cleaning“ and „Mainte-
nance“ chapters. The air circulation
prevents unpleasant odors and mold
spores from forming in the refrigerator
compartment.
• Make sure that the cooler is level du-
ring transport and stands securely on
all four feet.
• Secure the cooler against slipping
when transporting it in a vehicle.
Improper storage can damage the fresh-
ness cooler. Never leave the freshness
cooler in a place where it is exposed to
direct sunlight. The freshness cooler can
be damaged by the high temperatures.
Please note that disruptions to the Wurm
system will occur if you disconnect a
freshness cooler connected via a bus
connection from the mains by pulling the
mains plug out of the socket.
Productdetails and functionality
This chapter provides information on the
product details and functionality of the
freshness cooler and the individual com-
ponents that are important for the pro-
per handling of the freshness cooler.
Climate class
Cooling devices must always correspond
to one of the climate classes 0 to 8 ac-
cording to the ISO 23953-2 standard. The
climate class specifies specifications for
the environment in which the device is
operated. The cooler is designed as a
device in climate class 3, for which a
maximum ambient temperature of 25°C
and a maximum relative humidity of 60%
are specified. If the actual temperatu
-
re and humidity values are above the
specified values, the energy efficiency of
the freshness cooler may decrease. If the
actual values significantly exceed the
specifications, functional restrictions of
the freshness cooler can be expected.
Only operate the cooler in an environ
-
ment that meets the requirements of
climate class 3.
Cooling unit
The cooling unit integrated in the fresh-
ness cooler begins to work with a delay
of around 2 minutes after the freshness
cooler is switched on. The freshness
cooler does not have a separate on/
off switch for the cooling unit, i.e. when
you connect the fresh food cooler to the
power supply, you put it into operation
at the same time. Take all the necessary
preparatory measures before you con
-
nect the freshness cooler to the power
supply (see chapter Commissioning).
Housing and cooling storage
The freshness cooler is structured as fol-
lows:
• In the lower part „machine compart-
ment“ is the cooling system and the
electrics.
• The four outer panes of glass form the