KMS Fuel/FA23 manual
Version 3.01
24
7
Specifications
Minimum system requirements:
Windows 95,98,2000,NT,ME,XP or Vista
Internal memory 32Mb
Screen resolution 1024x768
Serial port or standard USB port
CD-ROM station
Acrobat reader 3.0 or higher (Acrobat reader 5.0 is included on the CD-ROM supplied)
ECU specifications:
Supply voltage 8.5 - 16 volts
Power consumption 200mA at 12 volts
5 volt supply to sensors can have a maximum of 100mA
Inputs:
Inputs are protected up to 50 volts.
Input for coolant and air temperature is suitable for an NTC-sensor as standard.
(2,2 kOhm at 25 degree celsius)
Input for engine load is suitable for potentiometers, air mass meters and map sensors with an
output between 0 and 5 volts.
Outputs:
Injector output can deliver at most 7 amps at 12 volts (for instance 6 injectors with a resistance of
16 ohms)
AUX and fuel pump outputs: max. 1 amp at 12 volts per output
Dimensions:
KMS FA23
LxWxH: 85 x 85 x 40 mm
Weight: 280 gram
KMS Fuel
LxWxH: 111 x 67 x 22 mm
Weight: 200 gram