Klippel R&D System
KCS Monitor Reference
23
2.2.12
Setup
You find additional information about KCS setup, hardware platform and initial KCS data here.
2.3
Alignment
This section describes the filter types available for the high pass filter alignment. See
tips how to use this feature and to incorporate it in the system tuning process.
Second Order Alignment
Only available for 2
nd
order systems (sealed boxes or transducer in free air). Replaces the given
systems resonance frequency and Q-factor by a desired cut-off frequency and Q-factor.
The target transfer function is defined as
𝑯
𝒑,𝒇𝒂𝒓
(𝐬) =
𝐬
𝟐
𝒔
𝟐
+
𝐬𝝎
𝒄
𝑸 + 𝝎
𝒄
𝟐
with Q denoting the target quality factor and
𝝎
𝒄
the desired cut-off frequency in radians.
Butterworth and Chebychev Alignments
These alignment types are available as 4
th
and 6
th
order filter types. The target transfer function for a