filtering unit

  STRONG

-

5000

-

S

        

                      

 

       

15.10.2019

 

   

 

Table No.2  

–  Replaceable Parts  –  Cartridge filter 

 

Type 

Weight

  

[kg] 

Filtration 

efficiency 

[%]

 

Quantity 

[pieces] 

Remarks 

 

PN105032T 

4,2 

99,9 

replacement frequency 

– 2 years 

 
Table No.3  

–  Additional equipment

 

Reducer  

400 x 400 / Ø500 

Additional silencer 

Elbow 

 

Type 

 

Type

 

 

Type 

ZR-UF 

TK-UF

 

KL-UF 

 

5.  Structure and Function 

STRONG-5000-S

 

filtering unit consists of subsequent elements: 

– 

fan 

– horizontal silencer, 

– 

housing  

–  4 cartridge filters inside, 

– 

pneumatic filters regeneration system 

– compressed air tank and electromagnetic valves, 

– 

hopper discharge underneath the housing, 

– 

waste container 

– connected with the hopper discharge, equipped with castor wheels,  

– 

four legs as a base for the housing, 

– 

connection fittings 

Ø400 – at the suction side along with steel dividers, as “spark-catchers”,  

– 

control unit. 

 
In case when the filtering unit is not connected (at the suction side) to the ventilation installation 
– i.e. the discharge connection is not closed and  the air is expelled back into the process room,  
it is recommended to apply additional sound absorbing elements  (see Fig. No.3). 
 
As optional accessories  KLIMAWENT S.A.  offers additional sound-absorbing set consisting of: 

– 

connecting fitting piece 

– an elbow 400x400 mm, 

– 

silencer Ø500 mm with a reducer. 

 
 

 

Содержание STRONG-5000-S

Страница 1: ...nt klimawent com pl www klimawent com pl 804U59 STRONG 5000 S 01 10 2019 EN Contents 1 Introductory Remarks 2 2 Application 2 3 Reservations of Producer 2 4 Technical Data 3 5 Structure and Function 4...

Страница 2: ...rective of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06...

Страница 3: ...ining viscous and aggressive contaminants as this would cause damage of the filters or forwarding the madia of temperature exceeding 60 C H Sources of ignition e g glowing parts cigarette butts embers...

Страница 4: ...nd electromagnetic valves hopper discharge underneath the housing waste container connected with the hopper discharge equipped with castor wheels four legs as a base for the housing connection fitting...

Страница 5: ...5 01 10 2019 filtering unit STRONG 5000 S Fig No 2 STRONG 5000 S Structure and dimensions...

Страница 6: ...e the appliance is protected with foil and placed on a transport pallet Having removed the protective foil put the filtering unit exactly on the foreseen place of use it is advised to use a fork lift...

Страница 7: ...nt that the locks can be bent fully aside and User can open the door widely to the right angle Insert the subsequent filter cartridges onto the slide guides and push them to the wall of the electro va...

Страница 8: ...lamp lights continuously to the moment when the failure is fixed Press the S2 STOP button one more time to stop the H3 light yellow lamp H4 signalling of the regeneration of the filters green button S...

Страница 9: ...rom short circuit overload and not complete phases function effects over current disconnector F1 protection for the transformer circuit and of the controller over current disconnector F2 protection fo...

Страница 10: ...FT higher level of the menu How to change the editable parameter OK marking illumination of the parameter RIGHT LEFT displacing the cursor between the fields that are possible to be marked UP DOWN cha...

Страница 11: ...ation stage of the filters STOP the device is being stopped after the alarm vanishes operator needs to delete it ALPR1 alarm signal of low pressure 1 ALPR2 alarm signal of low pressure 2 ALPR3 alarm s...

Страница 12: ...1 Sub menu of the settings COMMUNICATION 1 The function is not active in the program version 2 0 up to 2 2 INPUTS OUTPUTS Screen INPUTS OUTPUTS Sub menu of the settings INPUTS OUTPUTS Day Tu hour 10 0...

Страница 13: ...activated initial regeneration SWF TEMP REG NONE AL24V akt OFF Screen MODES 2 6 TEMP REG NONE I HEAT I COOL NONE disconnected the controlling with output OUT5 in function of temperature HEAT activated...

Страница 14: ...the status at inputs DI0 up to DI3 ALPR akt OFF Cons START OFF Screen MODES 4 6 ALPR AKT OFF and ON OFF blocking of the occurring alarm ALPRi at the inputs DI0 up to DI3 ON alarm ALPRi at the inputs D...

Страница 15: ...ve Input DI6 fulfils the same function as the button FILTER S3 on the elevation console DI8 START OFF DI8 STOP OFF Screen MODES 6 6 DI8 START OFF I ON OFF blocking of the possibility of activation by...

Страница 16: ...ectro magnetic valves during the status SWF Lsekwen Lon 0 9 cycles Lsekwen Lon number of sequences 4 cycles of pulsing each Time T12 0 5s Ton PowPause 10s Screen SETTINGS 2 6 Time T12 0 1 5 sec Time T...

Страница 17: ...lectromagnetic valves StanZas 24V state of the fuse of the transformer 24VAC of the power supply of the electromagnetic valves Time T22 0 5s Lsekwen Loff 02 Screen SETTINGS 4 6 Time T22 1 99sec Time T...

Страница 18: ...ro valves AktPoziomWe LO I HI AktPozimWe the level of signal from the input of pressure control is activated Tset 21 0 C Screen SETTINGS 6 6 Tset 10 60 Tset the applied temperature for the controlling...

Страница 19: ...atus of the analogue input 0 10V TO status of the outputs of impulses T1 T4 Tb 25 5 0 C StanZas 24 OK Screen INPUTS OUTPUTS 3 3 Tb measuring of temperature on the controller StanZas 24V the state of t...

Страница 20: ...larm blocks the sys tem function until the alarm stops After the alarm reason is fixed press the S2 STOP button one more time this will delete the H3 lamp In case of the adjusted parameter Cons STOP O...

Страница 21: ...Close the dewatering valve when exclusively clean and dry air is discharging from the installation The construction of the extraction fan and motor guarantees the work of the unit without the routine...

Страница 22: ...MPa Repair should be carried out after the fan is switched off and the device is disconnected from the power supply mains 11 Transport and Storage STRONG 5000 S filtering unit has to be transported i...

Страница 23: ...energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Par liament and of the Council with rega...

Страница 24: ...24 filtering unit STRONG 5000 S 15 10 2019 NOTES...

Отзывы: