![Klimawent SPLENDID VAC 200-S Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/klimawent/splendid-vac-200-s/splendid-vac-200-s_use-and-maintenance-manual_1977920002.webp)
Klimawent
– the warranty of highest quality at attractive price
2 z 8
Filtering unit
SPLENDID VAC 200
05.11.2019
INTRODUCTION
The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of
application, assembly, start-up and operational use of the
SPLENDID VAC 200
filtering unit.
Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction.
With regard to continuity of work carried on improvement of our products, we reserve for
ourselves the revision possibility of the draft and technological changes improving their
functional features and safety.
Construction of
SPLENDID VAC 200
meets the requirements of the current state of technology as well as the
safety and health assurances included in:
2006/42/EC Directive
of the European Parliament and of the Council of the 17 May, 2006 on machinery,
amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24);
2014/35/EC Directive
of the European Parliament and of the Council of the 26 February, 2014 on the harmo-
nisation of the laws of the Member States, relating to the making available on the market of electrical equipment
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014;
Is in accordance with the subsequent harmonised standards:
EN ISO-12100:2012
Safety of machinery
– General principles of design – Assessment and reduction of hazard
EN 60204-1:2018-12
Safety of machinery
– Electrical equipment of machines – Part 1: General requirements
EN ISO 13857:2010
Safety of machinery
– Safe distances to prevent hazard zones from being reached by up-
per and lower limbs
PURPOSE
As a high-pressure category
SPLENDID VAC 200
filtering unit is designed for extraction and filtration of various
sorts of dry dusts that are not aggressive or do not create explosion hazard. Especially, it is applicable for capturing
the welding fumes at mobile workplaces. It is a perfect solution for fume extraction through welding torches with
an integrated extraction unit (automations for welding in gas shields). Additionally, it can be connected to the wel-
ding faceshields with extraction or to other small local exhausts.
Do not apply the filtering unit for fatty fumes emitted during the point welding or welding the oil-laden steel sheets
with supportive agents stimulating the welding process (e.g. silspaw). Basic accessory is the high-vacuum suction
turbine and the polyester fabric cartridge filter. Therefore the appliance provides efficient capture of small dust
particles, even below 0,4
m.
RESERVATIONS OF MANUFACTURER
Manufacturer accepts no liability for any consequences following from the operational use that is in
contradiction to the purpose of application.
Installing of any additional elements that are not belonging to the normal device structure (or accessory
set) is not acceptable.
Do not introduce any structural or constructional modifications on the device on
one’s own.
Protect the appliance from mechanical damage.
The filtering unit cannot be used for extraction of the air containing viscous and aggressive contaminants
that would damage the filters, or for dusts creating explosion hazard.
In the course of operational use, any ignition sources, i.e. cigarettebutts / embers must not get
drawn into the filtration chamber
.
TECHNICAL DATA
Table No.1
Type
Maximum
vacuum of the
suction turbine
Suction
efficiency
Motor rate
Supply
voltage
Acoustic
pressure level
Weight
[Pa]
[m
3
/h]
[kW]
[V; Hz]
[dB(A)]
[kg]
SPLENDID VAC 200-S
30000
225
1,6
230; 50
72
30,5
SPLENDID VAC 200-A
30000
225
1,6
230; 50
72
31,0
CAUTION
:
1
) filtration efficiency 99,9%
2
) marking: S
– manual control; A – automatic control
3
) capacity of the waste container 15 dm
3
Spare parts
Table No.2
– Cartridge filter
Type
Weight
[kg]
Filtration efficiency
[%]
Remarks
PN032032U
4,2
99,9
replacement frequency
1
– 2 years