acid-proof extraction arms

  ERGO

-

MINI  

 

 

7.

 

Operational Use 

Construction of the device assures reliable function  without continuous routine technical su- 
pervision.  In each of the arm joints is introduced a friction ring to keep the required operatio- 
nal position during the work. Tightening the knurled nuts increases the friction moment, whe- 
reas,  their releasing reduces the friction.  Adjustment of the frictional brakes (in subsequent 
joints) provide self-supporting properties  and position balance of the device during the func- 
tion.  On the other hand,  the brakes should not be tightened to strong,  as this would cause 
excessive friction / resistance while the operator changes the arm position.   
During the work the position of the arm and the suction hood can be changed many times, to 
obtain to best arm configuration, according to the User’s current needs.  
After the work is completed, switch off the extraction fan  or, if the device works with a statio- 
nary extraction system,  close the shut-off damper on the suction hood.  
 

8.

 

Troubleshooting Guide 

 

Problem 

Possible reason 

Corrective action  

1

.  the extraction arm is falling  incorrectly adjusted joints 

increase the tension onto the 

 

 

 

friction ring by tightening the 

 

 

 

knurled nuts 

2

.  decrease in the volume 

the shut-off damper is closed  open the shut-off damper 

 

of the suction air 

in the extraction arm a barrier  remove the barrier object / 

 

 

object got stack in the extrac-  impurity 

 

 

tion arm 

 

 

9.

 

Maintenance 

The construction  of the device provides  longevity  and reliable function without the constant 
routine technical supervision.  During the maintenance  check the points of mechanical faste- 
ning, the joints and the swivel bearing. Systematically, remove the impurities from the suction 
hood / suction pipe.  
After one year of operational use,  carry out technical revision, replace or repair the faulty ele- 
ments, in case when this has been noticed during the technical check. 
 
Servicing is carried out by KLIMAWENT S.A. 81

–571 Gdynia, ul. Chwaszczyńska 194  tel. 58 

629 64 80. 

 

10.

 

Occupational Health and Safety 

ERGO-MINI extraction arms will not cause any hazard under the condition that they are firmly  
and correctly installed.  Operational use of the arm is easy and safe for the operators.  During 
the use observe strictly the regulations of the Occupational Health and Safety. 
Manufacturer is not responsible for defects / malfunctions resulting from the device application 
that is in contradiction with its purpose of use, or when changes have been introduced by user 
on one’s own. 
 

11.

 

Transport and Storage 

The devices ought to be stored in dry room and in areas of efficient ventilation. During the tran- 
sport / reloading protect the device from mechanical damage, scratching, indents, package da-
mage and pay attention that the surface markings do not get detached / obliterated.  
 

 

Содержание ERGO-MINI

Страница 1: ...ervations of Producer 2 4 Technical Data 3 5 Structure and Function 3 6 Assembly and Start up 4 7 Operational Use 5 8 Troubleshooting Guide 5 9 Maintenance 5 10 Occupational Health and Safety 5 11 Tra...

Страница 2: ...0 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction 2 Application ERGO MINI acid proof extraction arms are designed for removal the dust and gase...

Страница 3: ...pe Part No Range d A B C D Weight Flow resistances at volume flow 120m h mm mm mm mm mm mm kg Pa ERGO MINI K 50 3 950 810R53 720 60 280 360 260 100 2 5 490 ERGO MINI K 75 3 1150 810R59 950 80 265 460...

Страница 4: ...of the given arm type Additional flow adjustment is pro vided by the installed shut off damper 6 Assembly and Start up ERGO MINI extraction arms can be configured in a free chosen way depending on th...

Страница 5: ...f damper of the suction air in the extraction arm a barrier remove the barrier object object got stack in the extrac impurity tion arm 9 Maintenance The construction of the device provides longevity a...

Страница 6: ...e KLIMAWENT S A address 81 571 Gdynia Chwaszczy ska 194 A person authorized for issuing the technical documentation Teodor wirbutowicz KLIMAWENT S A hereby declares that the appliance name extraction...

Страница 7: ...7 10 01 2019 acid proof extraction arms ERGO MINI NOTES...

Страница 8: ...8 acid proof extraction arms ERGO MINI 10 01 2019 NOTES...

Отзывы: