Klimawent ERGO-KOS-AL Скачать руководство пользователя страница 11

 

 11 

 

 

 

 

30.01.2019

                                       

extraction rail

  ERGO-KOS-AL  

 

 

9.

 

Maintenance 

The maintenance consists in following steps: 
●  In order to obtain appropriate capture efficiency  of the suction hood, clean its surface and 

the inlet wire-mesh net from the deposited dusts and impurities. 
In case of welding dusts,  additionally  

– sprinkle the hood with  an anti-spattering liquid to 

avoid adhering / clinging the welding chippings. 

●  In case when the extraction arm is losing its self-supporting properties – undertake adust-

ment of its frictional brakes  (to regain self-locking function of the joints). 

●  Lubricate the swivel  every 3 months,  using solid grease  (lubrication nipple  is located in 

the swivel flange). 

●  After 1 operational year,  submit the device  to a technical revision  and  repair or replace  

the faulty element. 

●  Clean the internal surfaces of the extraction conduits (segment ducts) from the deposited 

impurities.  Revision frequency depends on the operational intensity.  

Every three months, it is recommended to examine the pollution state of the discharge 
conduits and clean them when relevant

 

10.

 

Occupational Health and Safety 

The ERGO extraction arms  will not cause any risk provided  that they are firmly and correctly 
mounted to the wall or another structural element of the building.   

 

 

   Unsure installing could cause uncontrolled detachment of the device  

and cause severe hazard to personnel / people in the vicinity

Start-up and maintenance are exclusively possible  after getting acquainted  with the contents  
of the present Use and Maintenance Manual. 
For the safety reasons, connect the device to the power supply system according to the being  
in force regulations within the range of personal protection against the electrical shock and the 
short-circuit- and overload effects. 

 

 

 Any activities related to device connection to the power supply system 

should to be performed by an authorised  person with qualifications.

 

Maintenance and repairs should be executed after the appliance is switched off and dis- 
connected from the power supply system. 

It is important to control the impeller rotation sense  of the fan, it should be according to the ar- 
row on the housing  (for 230/400V; 50Hz only).   Having completed the work,  leave the extrac- 
tion arm  in the ultimate operational position,  in case when  it constitutes  barrier to User / per- 
sonnel in the vicinity,  set the arm into home position. 
 
 

11.

 

Transport and Storage 

For the time of transport the duct segments are in packages  to protect them from mechanical 
damage.   
Extraction arms are conveyed in a partly assembled state,  in special packages.  The devices 
ought to be stored in dry rooms and areas of efficient ventilation. 
The transport / reloading  ought to eliminate  the hazard  of damage, scratching, indents of the 
elements of the system.   
Pay attention that the packages would not get damaged, and the markings on  
the surface would not get obliterated or detached. 
 

 

Содержание ERGO-KOS-AL

Страница 1: ...cation 2 3 Reservations of Producer 2 4 Technical Data 2 5 Structure and Function 4 6 Assembly and Start up 4 7 Operational Use 10 8 Troubleshooting Guide 10 9 Maintenance 11 10 Occupational Health an...

Страница 2: ...pts general principles for design Risk assessment and risk reduction 2 Application ERGO KOS AL is designed for extraction of welding fumes at mobile workplaces for linear wel ding of elements of lengt...

Страница 3: ...n Sort of the connection Type Part No Diameter Remarks for axial connection KPC 804K20 160 To connect the suction duct to the extraction installation Duct hanger Sort of the hanger Type Part No Remark...

Страница 4: ...elding the operator displaces the ERGO extraction arm with the trolley along the suc tion duct The suction hood ought to be adjusted at a distance at least ca 30 cm from the wel ding point Fig No 1 ER...

Страница 5: ...tion duct Slide the OP ERGO L trolley into the KOS AL suction duct in such a way that the trolley rollers are displacing on the side guide rails of the duct profile two straps of the rubber apron shou...

Страница 6: ...uction side of the fan connecting the self tightening duct with the fan c roof fan Extraction system with a fan for indoor installing a assembly of the KOS AL self tightening suction duct and trolley...

Страница 7: ...7 30 01 2019 extraction rail ERGO KOS AL Fig No 5 Fig No 6...

Страница 8: ...type T before the fan inlet the silencer length ought to be not less than 500 mm to connect the inlet and outlet of the fan with the installations by means with a flexible joint Flexible joints do no...

Страница 9: ...A 6 E 1 N 3000 230 0 75 54 83 75 69 61 2500 1700 21 WPA 6 E 3 N 3000 3 x 400 0 75 54 83 75 69 61 2500 1700 WPA 7 E 1 N 3000 230 1 1 54 86 74 72 60 3100 1800 23 WPA 7 E 3 N 3000 3 x 400 1 1 54 86 74 72...

Страница 10: ...fficiently eliminates the fume and dustiness not causing excessive draft During the operational use the position of the extraction arm and of the shut off lever can be changed several times adapting t...

Страница 11: ...evere hazard to personnel people in the vicinity Start up and maintenance are exclusively possible after getting acquainted with the contents of the present Use and Maintenance Manual For the safety r...

Страница 12: ...ion and with the present Use and Maintenance Manual mechanical damages and malfunctions caused by User changes modifications introduced by User on one s own malfunction resulting from the normal opera...

Страница 13: ...13 30 01 2019 extraction rail ERGO KOS AL...

Страница 14: ...030 335 160 Fig No 10 ERGO LUX L 2 ERGO LUX L 3 extraction arms Type L m A mm B mm C mm D mm E mm nxF mm G mm ERGO FLEX LUX 2 2 0 930 435 355 160 194 6x 6 5 295 ERGO FLEX LUX 3 3 0 1510 846 355 160 19...

Страница 15: ...Parliament and of the Council of May 17th 2006 on machinery amen ding the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The appliance meets following harmonized standard EN ISO 12100 2...

Страница 16: ...16 extraction rail ERGO KOS AL 30 01 2019 NOTES...

Отзывы: