RADIAL  ROOF  FANS

  BULLET-N 

 

 

F. 

BULLET-N fans cannot be 

used for

 

conveying the air contaminated with a mixture of 

flammable substances in form of gas, vapour, mist and dust, that in connection with 
the air could create the explosive atmosphere. 

G. 

Do not use the fans

  

for conveying the air containing viscous impurities that could ac-

cumulate on the device surface, especially on the impeller. 

H. 

Neither 

use 

it

 for forwarding the air with aggressive pollutants which will destructive- 

ly effect the device structure. 

I. 

During operation, the maximum impeller rotations should not exceed the nominal rotations. 

J. 

Producer is not responsible for wounds, injuries, body 

laceration experienced by User

 or per-

sonnel during the improper operational use. 

 

4.

 

Technical Data 

Table No.1 
Type 

 Supply   
 voltage 

  Rotations 

 Motor   
  rate 

 Maximum 
volume flow 

Maximum 
vacuum 

 Weight 

 

[v / Hz] 

[1/min] 

[W] 

[m³/h] 

[Pa] 

[kg] 

BULLET-160 

230 / 50 

2220 

54 

440 

280 

6,0 

BULLET-200 

230 / 50 

2670 

124 

1000 

520 

7,0 

BULLET-250 

230 / 50 

2600 

160 

1300 

600 

8,0 

BULLET-315 

230 / 50 

2480 

242 

1500 

730 

8,3 

CAUTION

:

 

Ingress protection IP44 

 

Synchronous rotations 

– 300 r.p.m 

 

 

 

Flow chart 

– BULLET-160-N 

 

        Table No.2 

– Acoustic pressure level

 [dB(A)] 

BULLET-160-N 

outlet 

inlet 

1  [m] 

5  [m] 

10  [m] 

15  [m] 

1  [m] 

57 

47 

40 

36 

48 

 

 

Содержание BULLET-160-N

Страница 1: ...3 5 Structure and Function 5 6 Assembly and Start up 6 7 Operational Use 8 8 Trouble Shooting Guide 8 9 Maintenance 8 10 Occupational Health and Safety 9 11 Transport and Storage 9 12 Terms of warran...

Страница 2: ...rective of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06...

Страница 3: ...ure I During operation the maximum impeller rotations should not exceed the nominal rotations J Producer is not responsible for wounds injuries body laceration experienced by User or per sonnel during...

Страница 4: ...4 RADIAL ROOF FANS BULLET N 31 05 2019 Flow chart BULLET 200 N Table No 3 Acoustic pressure level dB A BULLET 200 N outlet inlet 1 m 5 m 10 m 15 m 1 m 63 53 46 43 55 Flow chart BULLET 250 N...

Страница 5: ...e introduced under neath the roof bases TPD N or TPDC N 5 Structure and Function A cylindrical ABS plastic housing contains a radial impeller with a motor The housing is protect ted with a plastic hoo...

Страница 6: ...cut off the power supply during the servicing Isolating swi tches are in the assortment of KLIMAWENT S A as additional equipment delivery on sepa rate order The switch ought should be installed by Us...

Страница 7: ...UTION 1 Overload protection has to be selected by the investor 2 Suggested installing place of the isolating switch near the fan 3 Insulation class I 4 Ingress protection IP44 Fan Motor rate Turbine m...

Страница 8: ...Construction provides operational longevity robustness reliable function under the condition of appropriate operational use To obtain correct function of the fan and to observe the principles of Occup...

Страница 9: ...the PE protective cable Any technical revisions and activities connected with repair have to be executed necessarily after the device disconnection from the power supply system isola ting switch 11 T...

Страница 10: ...ts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requir...

Страница 11: ...11 31 05 2019 RADIAL ROOF FANS BULLET N NOTES...

Страница 12: ...12 RADIAL ROOF FANS BULLET N 31 05 2019 NOTES...

Отзывы: