Klimawent BIG-5000/Ex Скачать руководство пользователя страница 16

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

16 z 16 

Filtering unit

 

BIG-5000/Ex

 

08.10.2019 

 

 

DECLARATION  OF  CONFORMITY 

 

 

DECLARATION  OF  CONFORMITY  EC  No

. _______________ 

Manufacturer  (eventually also the authorised representative / importer): 

name:

 

KLIMAWENT S.A.

 

address:

 

81-571 GDYNIA, ul. 

Chwaszczyńska 194

 

 

A person, authorised for issuing the technical documentation: 

name and address:

 Teodor 

Świrbutowicz, 

KLIMAWENT

 

S.A.

 

 

hereby declares that the product: 

Filtering unit

 

type / model:

 

BIG-5000/Ex

 

serial number:___________________ 

year of production: ___________________ 

 

Meets the requirements of the subsequent European Directives: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 

2014/35/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the making available on the market of electrical equipment 
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014; 

2014/34/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the equipment and protective systems intended for use in 
potentially explosive atmospheres / Official Journal EC L96 of the 29.03.2014 / 

1999/92/EC Directive of the Council

 of the 19 December, 1999 on minimum requirements regarding safety of 

health  protection  of  workers  employed  at  workplaces  where  explosive  atmosphere  is  likely  to  occur  /  Official 
Journal No.138, Pos. 931/ 

is in accordance with the requirements of the following harmonised standards: 

EN ISO-12100:2012

      

  

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

EN 60204-1:2010  

      

  

Safety of machinery 

– Electrical equipment of machines  –  Part 1:  General requirements 

EN ISO 13857:2010    

Safety  of machinery 

– Safe distances to prevent hazard zones from being reached by 

upper and lower limbs 

EN  60079-0:2013-03/A11:2014-03

    Electrical  appliances  in  areas  of  gas  explosion  hazard 

– Part 0: General 

requirements 

EN 1127-1:2011  

Explosive atmospheres 

– Explosion prevention and protection.  Basic terminology and 

methodology 

EN ISO 80079-36:2016-07  

Explosive atmospheres 

– Part 36: Non-electrical appliances in areas of explosion 

risk Methodology and requirements 
 
 
 

 
 
 
 

 

 

 

 

place, date 

 

signature of the 

authorised person 

 

name, surname, 

function of the signatory 

 

 

Содержание BIG-5000/Ex

Страница 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Страница 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Страница 3: ...tional use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3 3 Operator should wear antistatic clothes while emptying the waste conta...

Страница 4: ...er They have been classified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 5000 Ex filtering unit consists of three functional assemblies Regeneration...

Страница 5: ...ils described in separate Use and Maintenance Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in the test st...

Страница 6: ...arge dimensions At the upper part of the regeneration chamber are installed lifting hooks for lifting and positioning during the transport and assembly activities After the chamber of filters is conne...

Страница 7: ...n sorts Any activities related to the installing necessarily must be performed by a specialised assembly team after being instructed Having completed the assembly check the conductivity between the su...

Страница 8: ...ned to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assemblies switc...

Страница 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Страница 10: ...from dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages o...

Страница 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Страница 12: ...the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out its their reason and remove t...

Страница 13: ...Dust emerges outside the devi The cartridge filter is not tightly con Replace the cartridge filter or ce nected of damaged improve its mounting The dust is of another sort than stated Contact the manu...

Страница 14: ...system During these activities it is important to wear antistatic clothes While emptying the waste container of the dust during the dismantling of the container and its mounting the waste container mu...

Страница 15: ...d device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User device failures caused during the use which is in contradiction with the...

Страница 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Отзывы: