Klimawent BIG-12000/Ex Скачать руководство пользователя страница 1

EN 

 

USE AND MAINTENANCE MANUAL 

 

 

 

  

Filtering unit  BIG-12000/Ex 

 

 

 

           

 

(

KOMPAC AIR 325 4x4 12000

)

 

 

ATEX marking: 

 

II 3 D Ex tD A22 T200

ºC

 

Contents

:

 

 

INTRODUCTION ......................................................................................................................................................... 2

 

 

PURPOSE ................................................................................................................................................................... 2

 

 

RESERVATIONS  OF  MANUFACTURER .................................................................................................................. 3

 

 

TECHNICAL  DATA ..................................................................................................................................................... 3

 

 

STRUCTURE  ADN  FUNCTION ................................................................................................................................. 4

 

 

ASSEMBLY  AND  STARTUP ..................................................................................................................................... 5

 

 

OPERATIONAL  USE .................................................................................................................................................. 8

 

 

TROUBLESHOOTING  GUIDE .................................................................................................................................. 14

 

 

MAINTENANCE  AND  REPAIR ................................................................................................................................ 14

 

 

OCCUPATIONAL  HEALTH  AND SAFETY .............................................................................................................. 15

 

 

TRANSPORT   AND  STORAGE ............................................................................................................................... 15

 

 

TERMS  OF  WARRANTY ......................................................................................................................................... 16

 

 

DECLARATION  OF  CONFORMITY ........................................................................................................................ 16

 

 

10

.

10

.

2

0

1

9

 

Producer: 

KLIMAWENT S.A. 

81-

571 Gdynia, ul. Chwaszczyńska 194 

tel. 58 629 64 80, 58 771 43 40 
fax 58 629 64 19 
email

[email protected]

 

 

www.klimawent.com.pl

 

issue:

 October 2019

 

 

 

Содержание BIG-12000/Ex

Страница 1: ...URE ADN FUNCTION 4 ASSEMBLY AND STARTUP 5 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 14 MAINTENANCE AND REPAIR 14 OCCUPATIONAL HEALTH AND SAFETY 15 TRANSPORT AND STORAGE 15 TERMS OF WARRANTY 16 DECLARATI...

Страница 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Страница 3: ...es close to the filtering unit and in the vicinity 3 5 At the side of decompression panel it is important to create a hazard area of potential explosion according to the Fig No 5 This area should be f...

Страница 4: ...losion Outside the chamber is installed a micro controller to activate the electromagnetic valves described in details in Section 7 Supporting construction along with the hopper chamber Underneath the...

Страница 5: ...ng structure seal up the join surface with silicone and screw it up thoroughly with bolts The screws bolts and silicone are delivered by manufacturer along with the device The compressed air tank and...

Страница 6: ...ing instructed Having completed the assembly check the conductivity between the subsequent parts of the device and check if the maximum resistance does not exceed 106 Ohm Grounding of the device and o...

Страница 7: ...imawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 7 z 16 Fig No 6 Connection Diagram 1 3 Fig No 7 Connection Diagram 2 3 Fig No 8 Connection Diagram 3...

Страница 8: ...control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system co...

Страница 9: ...The A3 terminal box connects the cable to the sensors on the venting panel with the output cable going out of the Switchgear A1 When the cable on the panel is interrupted during the explosion the devi...

Страница 10: ...Klimawent the warranty of highest quality at attractive price 10 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Страница 11: ...Klimawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 11 z 16...

Страница 12: ...Klimawent the warranty of highest quality at attractive price 12 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Страница 13: ...o controller controlling the function of the electromagnetic valves description in 7 2 These alarms are signalised by the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it i...

Страница 14: ...s of ALARM during the function are described in Section 7 OPERATIONAL USE MAINTENANCE AND REPAIR 9 1 Cartridge filters It is necessary to undertake a visual control of the cartridge filters at any cas...

Страница 15: ...ed with the contents of the present Use and Maintenance Manual For safety reasons the device must be connected to the power supply system strictly according to the enclosed Connection Diagram and with...

Страница 16: ...6 page 24 2014 35 EC Directive of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the making available on the mark...