INTRODUCTION 

The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of 
application, assembly, start-up and operational use of the 

BIG-10000/Ex

 Filtering unit. 

 

Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction. 

 

With regard to continuity of work  carried on improvement of our products, we reserve for 
ourselves  the  revision  possibility  of  the  draft  and  technological  changes  improving  their 
functional features and safety.

 

Construction of 

BIG-10000/Ex

 meets the requirements of the current state of technology as well as the safety and 

health assurances included in: 
the safety and health assurances included in: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 

2014/35/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the making available on the market of electrical equipment 
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014; 

2014/34/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the equipment and protective systems intended for use in 
potentially explosive atmospheres / Official Journal EC L96 of the 29.03.2014 / 

1999/92/EC Directive of the Council

 of the 19 December, 1999 on minimum requirements regarding safety 

of health protection of workers employed at workplaces where explosive atmosphere is likely to occur / Official 
Journal No.138, Pos. 931/ 

Is in accordance with the subsequent harmonised standards: 

EN ISO-12100:2012

    

 

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

EN 60204-1:2018-12   

Safety of machinery 

– Electrical equipment of machines  – Part 1:  General requirements 

EN ISO 13857:2010    

Safety of machinery 

– Safe distances to prevent hazard zones from being reached by up-

per and lower limbs 

EN  60079-0:2013-03/A11:2014-03

    Electrical  appliances  in  areas  of  gas  explosion  hazard 

–  Part  0:  General 

requirements 

EN 1127-1:2011  

Explosive atmospheres 

– Explosion prevention and protection.  Basic terminology and me-

thodology 

EN ISO 80079-36:2016-07  

Explosive atmospheres 

– Part 36: Non-electrical appliances in areas of explosion risk 

Methodology and requirements

 

 

PURPOSE 

BIG-10000/Ex

   is  appropriate for cleaning the  dust  laden air from 

dry

 dust particles, arising during  production 

processes with occurrence of powdery materials and dust particles of ST1 explosiveness class. The appliance is 
equipped with 9 cartridge filters, with antistatic polyester membrane 

– functioning on the basis of surface filtration. 

Admissible maximum temperature of the filtered air is 40ºC. 
The device can be applied for such processes as: 

– 

grinding of non-sparking materials, 

– 

sand blasting, shot peening, 

– 

mechanical cutting of metals, gas-, plasma-, laser-, arc cutting of metals, 

– 

polishing, planishing, 

– 

processing of plastics, 

– 

metalization, 

– 

powder varnishing. 

 

Basic advantages of the device are optimum filtration efficiency, long operational use (longevity) of the cartridge 
filters, low power consumption and simple and fast maintenance. The appliance is admitted for use, according to 
the Ex marking, for cleaning the air in areas of explosion hazard, according to the ATEX 137 1999/92/EC Directive. 

According to ATEX, the operational conditions are specified (as for this device) as follows: 
Ex II 3 D Ex tD A22 T200ºC.  The subsequent markings are interpreted as

:

 

 

group II  

–  the device is designed for work in enterprises, in on-ground premises, in sites of occur-

rence of explosion atmospheres, except for application in areas of methane hazard 

(

firedamp

)

, or risk 

connected with carbon dust

;

 

 

category 3 

– the device is designed for application in areas where explosive atmospheres are likely 

to occur, whereby the explosive atmospheres are of low risk

 

D hazard 

– flammable dusts

 

Ex tD A22 IP65 

– application of the implemented motor – as constructed and tested according to the 

European standards for application in areas of explosion hazard, with dust-proof housing and with 
the implemented protection against humidity

.

 

 

T200ºC – the  surface temperature of any part 

(

of  the  device

)

 

will not exceed 200ºC during normal 

operation. 

Содержание BIG-10000/Ex

Страница 1: ...UNCTION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 15 MAINTENANCE AND REPAIR 15 OCCUPATIONAL HEALTH AND SAFETY 16 TRANSPORT AND STORAGE 16 TERMS OF WARRANTY 16 DECLARATION OF CON...

Страница 2: ...Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gen...

Страница 3: ...0 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3...

Страница 4: ...ified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 10000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upp...

Страница 5: ...the fan chamber are delivered upon separate order 5 2 Function BIG 10000 Ex filtering unit provides separation of the air containing dry dust fraction The dust laden air is guided to the chamber of f...

Страница 6: ...ice of 9 cartridge filters and at the nominal diameter of the compressed air tank of 8 should be 1 1 2 6 2 Start up Upon first operation of the compressed air installation of the device check if the c...

Страница 7: ...erson according to being in force regulations in this range Any device modification change within the construction and mounting without the consent of deliverer shall cause the invalidation of conform...

Страница 8: ...al 7 1 Description of the control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed...

Страница 9: ...e price 08 10 2019 Filtering unit BIG 10000 Ex 9 z 20 Fig No 11 Switchgear A1 internal view Micro controller A2 provides control of the electromagnetic valves the function is described in Section 7 2...

Страница 10: ...omation disconnects the fan and the system of regeneration of filters Any electrical connections ought to be performed in conformity with the above placed Connection Diagram see Fig No 7 8 9 Motor in...

Страница 11: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 11 z 20...

Страница 12: ...Klimawent the warranty of highest quality at attractive price 12 z 20 Filtering unit BIG 10000 Ex 08 10 2019...

Страница 13: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 13 z 20...

Страница 14: ...the appliance is installed a temperature sensor At the moment when the temperature of the conveyed air exceeds 40 C an acoustic signal buzzer activates this is signalised by the H4 HIGH TEMPERATURE l...

Страница 15: ...filters are damaged or worn out replace them for new The filters should be drawn out beginning from the filter closest to the inspection door Before User draws out the filter first release the mountin...

Страница 16: ...nge of personal protection against electric shock Connection to the power supply system should be executed by an authorised person with electrical qualifications Maximum operational pressure of the co...

Страница 17: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in poten...

Страница 18: ...Klimawent the warranty of highest quality at attractive price 18 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Страница 19: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 19 z 20 NOTES...

Страница 20: ...Klimawent the warranty of highest quality at attractive price 20 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Отзывы: