Klimawent BIG-10000/Ex Скачать руководство пользователя страница 15

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

08.10.2019

 

Filtering unit

 

BIG-10000/Ex

 

15 z 20 

 

 

TROUBLESHOOTING  GUIDE 

Table No.3 

 

Problem 

Possible reason 

Corrective action  

1. 

 

Regeneration runs incorrectly, due  

Adjust to obtain the pressure of 

 

 

to too low pressure of the compres- 

0,6

0,8 MPa in the system 

 

 

sed air. 

 

 

Decrease in the inlet air volume  The cleaning time and work time 

Adjust the work of micro-controller  

 

after the period of correct fun- 

are not adjusted correctly 

according to the present Use and 

 

ction 

 

Maintanance Manual 

 

 

Too high humidity of the filters, cau- 

It is important to dewater the com- 

 

 

sed by the humid air in the compres- 

pressed air tank, check the state  

 

 

sed air system 

of the compressed air system 

 

 

Dust emerges in another area, due to  Limit the temperature at the inlet 

 

 

temperature higher than 40

C of the 

 

 

 

inlet air 

 

2

.  Dust emerges outside the devi-  The cartridge filter is not tightly con- 

Replace the cartridge filter or  

 

ce 

nected of damaged 

improve its mounting 

 

 

The dust is of another sort than stated  Contact the manufacturer 

 

 

in the instruction. 

 

 

 

Filtration efficiency is too low 

Contact the manufacturer 

3

.

 

Dust is appearing outside the 

The cartridge filter is damaged 

Replace the faulty element 

 

filtering unit  after a longer 

The mounting flange (of the cartridge   

 

period of correct work 

filter) is deformed or damaged 

Replace the faulty element 

 

 

MAINTENANCE  AND  REPAIR 

9.1  Cartridge filters 

It  is  necessary  to  undertake  a  visual  control  of  the  cartridge  filters,  at  any  case  when  the  waste  container 
(underneath the hopper chamber) is emptied of the dust. Examine the state of the mounting elements, the state 
of  the  filtration  surface,  the  degree  of  pollution,  the  presence  of  damages,  etc. 

– through the  inspection door. 

Additionally, this revision should be carried out in case when any improper function of the device is noticed.  
In case the cartridge filters are damaged or worn out 

– replace them for new. The filters should be drawn out,  

beginning from the filter closest to the inspection door. Before User draws out the filter,  first release the mounting 
nuts, turn the filter itself and take it out. 

 

9.2  Fan

 

Technical revision and maintenance of the fan should be executed according to the instruction of the fan.  In case 
when  faulty  function  of  the  fan  is  noticed,  please  contact  the  producer.  The  fan  motor  must  be  submitted  to 
systematic  maintenance,  to  provide  correct  function  and  safety.  Follow  steps  strictly  as  described  in  the 
instructions of the fan manufacturer. When necessary,  replace the fan or motor for new and this can be carried 
out exclusively by an authorised personnel. 
 

9.3  Compressed air tank.

 

The compressed air tank must be submit  to technical revision and maintenance, according to the valid regulation 
on the pressure devices. Periodically, examine all the connections on the compressed air tank.  It is important to 
dewater the tank, through the connection (installed in the lower part of the tank). 
 

9.4  Electromagnetic valves

 

Electromagnetic  valves  do  not  require  current  maintenance.  Simply,  it  is  sufficient  to  check  the  electrical 
connections, the state of grounding and tightness on the pneumatic installation.  
It is recommended to replace the valves after 2 years of use,  and not later than after 4 years of operational use 
(but in this case, contact the producer of the filtering unit). 
 

9.5  Recommended periods of technical revisions and maintenance of the filtering unit.

 

Table No.4 

Current check and action after the fill up state of the waste 
container 

Removal of dust from the waste container 

Current revision 

Systematic cleaning of the device and its assemblies, 
in order to avoid accumulating of the dust layer ex-
ceeding 5 mm 

Every time, the waste container is emptied 

Control visually the cartridge filters, through the 
revision door. 

Once a month 

Check the state of the device grounding, and examine 
the conductivity between the all assemblies of the 
device, if the maximum resistance does not exceed 
10

6

 Ohm 

Содержание BIG-10000/Ex

Страница 1: ...UNCTION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 15 MAINTENANCE AND REPAIR 15 OCCUPATIONAL HEALTH AND SAFETY 16 TRANSPORT AND STORAGE 16 TERMS OF WARRANTY 16 DECLARATION OF CON...

Страница 2: ...Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gen...

Страница 3: ...0 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3...

Страница 4: ...ified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 10000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upp...

Страница 5: ...the fan chamber are delivered upon separate order 5 2 Function BIG 10000 Ex filtering unit provides separation of the air containing dry dust fraction The dust laden air is guided to the chamber of f...

Страница 6: ...ice of 9 cartridge filters and at the nominal diameter of the compressed air tank of 8 should be 1 1 2 6 2 Start up Upon first operation of the compressed air installation of the device check if the c...

Страница 7: ...erson according to being in force regulations in this range Any device modification change within the construction and mounting without the consent of deliverer shall cause the invalidation of conform...

Страница 8: ...al 7 1 Description of the control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed...

Страница 9: ...e price 08 10 2019 Filtering unit BIG 10000 Ex 9 z 20 Fig No 11 Switchgear A1 internal view Micro controller A2 provides control of the electromagnetic valves the function is described in Section 7 2...

Страница 10: ...omation disconnects the fan and the system of regeneration of filters Any electrical connections ought to be performed in conformity with the above placed Connection Diagram see Fig No 7 8 9 Motor in...

Страница 11: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 11 z 20...

Страница 12: ...Klimawent the warranty of highest quality at attractive price 12 z 20 Filtering unit BIG 10000 Ex 08 10 2019...

Страница 13: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 13 z 20...

Страница 14: ...the appliance is installed a temperature sensor At the moment when the temperature of the conveyed air exceeds 40 C an acoustic signal buzzer activates this is signalised by the H4 HIGH TEMPERATURE l...

Страница 15: ...filters are damaged or worn out replace them for new The filters should be drawn out beginning from the filter closest to the inspection door Before User draws out the filter first release the mountin...

Страница 16: ...nge of personal protection against electric shock Connection to the power supply system should be executed by an authorised person with electrical qualifications Maximum operational pressure of the co...

Страница 17: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in poten...

Страница 18: ...Klimawent the warranty of highest quality at attractive price 18 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Страница 19: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 19 z 20 NOTES...

Страница 20: ...Klimawent the warranty of highest quality at attractive price 20 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Отзывы: