7.  Operational Use 

Construction of the device assures reliable function  without continuous routine technical su- 
pervision.  Adjustment of the ERGO extraction arms  consists in setting the frictional brakes 
that are in each joint.  Frictional brakes provide self-supporting properties and position balan- 
ce of the device during the function.  Tightening the nut tension  (upon the frictional element) 
increases the friction moment, whereas its releasing reduces the friction. 
The brake adjustment  in the following joints  ought to be  executed  in such a way that provi- 
des stability and self-supporting features of the extraction arm (which is important to keep the 
stable arm position),  whereas on the other hand, this cannot cause any excessive friction re-
sistance while User is changing the arm position. 
Having completed the adjustment,  tighten up the counter-nuts.  Placement of the adjustment 
nuts is illustrated in dimensional drawings of the extraction arms. 
 

8.  Troubleshooting Guide 

Table No.1 

 

problem 

possible reason corrective action 

1. 

The extraction arm is  

Improperly adjusted frictional brake. 

 

falling. 

Increase the tension upon frictional disks of the brake in the joint 
by tightening the adjustment nuts. 

2. 

The extraction arm 

The rotation axis of the arm is not positioned vertically. 

 

is automatically setting 

Carry out the positioning of the mounting flange of the 

 

always in the same 

ERGO/Ex extraction arm to set the rotation axis vertically. 

 

position. 

 

3. 

Drop in the air suction rate  Improper impeller rotation sense of the extraction fan. 

 

along with the increased  

Change the phase connection sequence (3-phase motor only). 

 

noise level. 

 

 

9.  Maintenance 

Maintenance consists in following steps executed periodically: 
●  In case when the extraction arm losses the self-supporting property in the joint system 

– undertake its adjustment. 

●  Every three months lubricate  the swivel with solid grease  (lubrication nipple is placed 

on the swivel collar. 

●  Periodically, (more frequently than once a half a year of use) undertake technical revi- 

sion and 

replace the faulty or worn out elements

  Systematically check the cleanness  of the extraction arm,  remove the dust that built 

up inside and on the device surface, in order to avoid self-ignition of the deposited im- 
purities.  

Cleaning can be executed beyond the area of explosion hazard

 

In case of replacement necessity  of any element in the extraction arm (i.e. gas 
spring, hose, pipe segments, hood, grounding cables), use original parts only, 
delivered by KLIMAWENT S.A. 

 

Any repairs ought to be executed in rooms not being in explosion hazard zone. 

 

After every disassembling, assembling,  check the continuity of the grounding 
cables. 

 

Periodically,  (depending  on the conditions of work)  measure the surface resi- 
stance of the hoses 

– it should not exceed 1 GΩ.  Execute the measuring accor- 

ding to the EN 13463-1 Clause 7.4.4 a.  Similarly,  measure the resistance of the 
device (continuity of the grounding cables) 

– should not exceed 1Ω. Collect the 

electrical measuring results in a file. 

 
 

 

Содержание 814R21

Страница 1: ...3 5 Structure and Function 5 6 Assembly and Start up 6 7 Operational Use 7 8 Troubleshooting Guide 7 9 Maintenance 7 10 Occupational Health and Safety 8 11 Transport and Storage 8 12 Terms of warrant...

Страница 2: ...O 80079 36 2016 07 Explosive atmospheres Part 36 Non electrical equip ment for explosive atmospheres Methodology and requi rements EN ISO 80079 37 2016 07 Explosive atmospheres Part 37 Non electrical...

Страница 3: ...of any additional elements not belonging to the normal device structure or acces sory set is not acceptable C Do not undertake any structural changes or constructional modifications on the device on o...

Страница 4: ...0 800 2280 ERGO L Z 2 R Ex 2110 1487 122 2213 ERGO L Z 3 Ex 2195 2888 922 3100 ERGO L Z 3 R Ex 2835 2092 409 3033 ERGO L Z 4 Ex 2732 3372 1266 3710 ERGO L Z 4 R Ex 3374 2561 573 3643 No Type Dimension...

Страница 5: ...ction arm and discharging the electrostatic loads to the grounding dissipation A full rotation swivel of stainless steel spark proof execution provides 360 rotation of the extraction arm around its ve...

Страница 6: ...WENT S A additionally provides installing the ex traction fans Wall brackets can be mounted on the wall or on another construc tion through stainless steel bolts M10 CAUTION Installing of the ERGO L Z...

Страница 7: ...always in the same ERGO Ex extraction arm to set the rotation axis vertically position 3 Drop in the air suction rate Improper impeller rotation sense of the extraction fan along with the increased C...

Страница 8: ...ompleted the work leave the extraction arm in the ultimate operational position in case when it constitutes obstacle to personnel set in into home position 11 Transport and Storage Extraction arms hav...

Страница 9: ...9 10 01 2019 explosion proof extraction arms ERGO L Z 2 3 4 Ex...

Страница 10: ...10 explosion proof extraction arms ERGO L Z 2 3 4 Ex 10 01 2019...

Страница 11: ...11 10 01 2019 explosion proof extraction arms ERGO L Z 2 3 4 Ex Grounding cables of the extraction arms ERGO L Z 2 3 4 Ex oraz ERGO L Z 2 3 4 R Ex 1 2 3 4 5 6...

Страница 12: ...armonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction EN 1127 1 2011 Explosive atmospheres Explosion prevention and p...

Отзывы: