Klimawent 802W06 Скачать руководство пользователя страница 3

 

 3 

 

 

 

 

04.06.2019                                

CHEM-PROOF STATIONARY FAN

  WPA-CHEM  

 

 

 

3.

 

Reservations of Producer 

A

.

 

Manufacturer accepts no liability

  

for any consequences following from the operational use 

that is in contradiction to the purpose of application. 

B

.

 

Installing of

 any additional elements not belonging to the normal device structure (

or acces

sory set) is not acceptable. 

C

.

 

Do not undertake

  

any structural changes  or constructional modifications on the device on 

one

’s own. 

D

.

 

Protect the appliance’s housing from mechanical damage. 

E

.

 

Prior to

 

installing

 check the load carrying capacity 

of the building structure

  

where the device  

will be mounted.  Unsure mounting could cause hazard to personnel/people in vicinity and  
effect in damage of the device. 

F

.

 

The fan cannot be 

used for

 

conveying the air contaminated with a mixture of flamma-

ble substances in form of: gas, vapour, mist and dust, that in connection with the air 
could create the explosive atmosphere. 

G

.

 

Do not use the fan

  

for conveying the air  containing viscous impurities that could ac-

cumulate on the device surface, especially on the impeller. 

H

.

 

During operation,  the maximum impeller rotations should not exceed the nominal rotations. 

I

.

 

Producer is not responsible for wounds, injuries, body 

laceration experienced by User

 or per-

sonnel during the improper operational use. 

 

4.

 

Technical Data 

Table No.1 

Type of the fan 

Synchro- Supply  Motor  Maximum  Maximum 

Acoustic 

 Weight  

 

nous 

voltage rate   Volume

 

vacuum 

pressure level  

 

rotations 

 

 

    flow

 

 

from distance

 

 

 

 

 

 

 

 

1m 

5m 

 

 

[r.p.m.] 

[V] 

[kW]    [

m³/h]

 

[Pa] 

[dB (A)] 

  [kg] 

WPA-CHEM-160/3000 

3000 

3x400 

0,37 

1100 

950 

71 

62 

14 

WPA-CHEM-200/1500 

3000?? 

3x400 

0,55 

2000 

900 

72 

63 

25 

WPA-CHEM-250/1500 

1500 

3x400 

0,25 

2000 

350 

64 

56 

30 

WPA-CHEM-300/1500 

1500 

3x400 

0,55 

3500 

530 

68 

59 

36 

WPA-CHEM-400/1000 

1000 

3x400 

0,55 

5500 

400 

68 

59 

60 

WPA-CHEM-500/1000 

1000 

3x400 

2,2 

12200 

720 

75 

66 

107 

1. 

Ingress protection  IP 55 

2. 

Maximum temperature of the conveyed air is +

40ºC.  Fans of special execution are adap- 

ted for function in temperature  +60ºC. 

3. 

Maximum dustiness of the conveyed air is  0,3 g/m

3

4. 

On demand are available fans of special execution for supply voltage 1 x 230V. 

 

 

Содержание 802W06

Страница 1: ...al Use 7 8 Troubleshooting Guide 7 9 Maintenance 7 10 Occupational Health and Safety 8 11 Transport and Storage 8 12 Terms of warranty 8 13 Table of resistance of PVC against various substances 9 14 Sample of the Declaration of Conformity 13 802W06 WPA CHEM 160 3000 04 06 2019 EN 802W07 WPA CHEM 200 3000 04 06 2019 EN 802W08 WPA CHEM 250 1500 04 06 2019 EN 802W09 WPA CHEM 300 1500 04 06 2019 EN 80...

Страница 2: ...uirements for energy related pro ducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Regulation of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Additionally the appliance meets followi...

Страница 3: ...or conveying the air containing viscous impurities that could ac cumulate on the device surface especially on the impeller H During operation the maximum impeller rotations should not exceed the nominal rotations I Producer is not responsible for wounds injuries body laceration experienced by User or per sonnel during the improper operational use 4 Technical Data Table No 1 Type of the fan Synchro...

Страница 4: ...an D a b h RD 0 F C G E L H B WPA CHEM 160 3000 160 162 118 263 188 202 150 218 385 501 310 WPA CHEM 200 3000 200 237 133 326 224 240 370 278 510 568 381 WPA CHEM 250 1500 250 297 166 398 280 297 405 308 545 698 473 WPA CHEM 300 1500 300 356 199 482 336 358 440 414 620 848 557 WPA CHEM 400 1000 400 474 265 617 447 470 580 514 680 1080 728 WPA CHEM 500 1000 500 500 315 715 500 570 640 640 730 1235 ...

Страница 5: ...d construction of two parallel walls strengthened with ribs Between the walls is located a spiral element of the housing The housing is made of plates of non plasticised polyvinylchloride To the housing disk is welded an inlet confusor The housing disk is fastened disconnectably at the front wall of the housing its easy dismantling provides free access to the impeller The inlet confusor is also ex...

Страница 6: ...ed during the transport The hole pattern of the foundation ought to be strictly according to the distribution of suitable holes in the fan base Additionally the holes placement of the inlet and outlet should be suitable with adequate holes of the ventilation ducts The fan must be placed strictly horizon tally if the device is not levelled use washers to obtain appropriate positioning Moreover it i...

Страница 7: ...8 Troubleshooting Guide Table No 3 Problem Possible reason Corrective action 1 Significant and sudden decre Obstacle objects reducing the air Clean the ventilation ducts ase of the intake air occurs flow got stack at the inlet grill 2 Sudden vibrations of the fan Obstacle objects reducing the air Disconnect the fan from are occurring flow got stack within the impeller the power supply system and r...

Страница 8: ...essarily after disconnection from the power supply system isolating switch 11 Transport and Storage For the transport time the fan should be protected against damage indentation crack etc Smaller fans can be forwarded in cardboard packages whereas the larger ones should be placed on a pallet protected with foil Use special transporting lines ropes attached at the pallet base or at the fan base in ...

Страница 9: ...l butyl alcohol 100 o Liquid chlorine 100 Dry gaseous chlorine 100 Potassium chlorate 7 3 o Sodium chlorate aqueous solution 25 Ammonium chloride aqueous solution all Zinc chloride Ethylene chloride 100 Methyl chloride 100 Potassium chloride aqueous solution saturated Sodium chloride domestic salt aqueous solution saturated Sodium chloride aqueous solution 5 Chlorobenzene 100 Cadmium cyanide Coppe...

Страница 10: ...Acetic acid icy 100 o Acetic acid aqueous solution 50 Oleic acid 100 o Sulphuric acid 3 50 96 o Sulphuric acid 50 10 Hydrochloric acid 35 Stearic acid 100 Oxalic acid saturated Acidic sodium carbonate aqueous solution saturated Acidic sodium sulphate aqueous solution saturated Nail lacquer o Lysol White liquor 12 5 of the active chlorine o Potassium lye 10 50 Potassium permanganate aqueous solutio...

Страница 11: ...da Vapours of tio urea Vapours of aliphatic hydrocarbons Gaseous ozone Automotive fuel normal petrol Automotive fuel petrol super Automotive fuel diesel oil Paraffin 100 Beer Brake fluid Anti freeze fluid di ethylene glycol Sodium hypochlorite aqueous solution 5 Liquid propane 100 Cresol solution Soap solution saturated Mercury 100 Rum 40 Potassium sulphate aqueous solution saturated Sodium sulpha...

Страница 12: ...ium carbonate aqueous solution saturated Sodium carbonate aqueous solution saturated Water 100 Chlorinated water saturated Aqua regia nitro hydrochloric acid Seawater Sodium hydroxide 50 Sodium hydroxide caustic soda 100 resistant conditionally resistant with the occurrence hazard of tensioning stress cracks 0 conditionally resistant low resistant not resistant ...

Страница 13: ...ments for energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input po wer between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 The appliance meets following harmonized sta...

Страница 14: ...14 CHEM PROOF STATIONARY FAN WPA CHEM 04 06 2019 NOTES ...

Страница 15: ...15 04 06 2019 CHEM PROOF STATIONARY FAN WPA CHEM NOTES ...

Страница 16: ...16 CHEM PROOF STATIONARY FAN WPA CHEM 04 06 2019 NOTES ...

Отзывы: