Klimawent 802W06 Скачать руководство пользователя страница 2

                                   2 

                                          

CHEM-PROOF STATIONARY FAN

  WPA-CHEM                   

 

       04.06.2019 

   

 

 

1.

 

Introductory Remarks 

The purpose of the present

  

Use

 and Maintenance Manual is to supply User  with directions wi- 

thin the range of application, installation, start-up and the use of the 

WPA-CHEM

 

chem

-proof 

stationary fans

.

 

 

Installing, start up and operational use are exclusively admissible after getting acquaint- 
ted with the contents of the Use and Maintenance Manual

With regard to continuity of work carried on 

improvement

 of our

 

products, we reserve for oursel- 

ves the revision possibility of the

 draft  and

  

technological changes improving their functional fea-

tures and safety. 

 

The construction of the

  

WPA-CHEM

 

chem-proof stationary fans 

meets

 the 

requirements of the

  

current state

  

of technology

  

as well as the safety and health assurances included in: 

  2006/42/EC

 

Machinery Directive 

of the European Parliament 

and of the Council of

 May 17

th

2006  on machinery 

– amending the 95/16/EC (recast)

 /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

  2014/35/EC Directive 

of the European Parliament and of the Council of February 26

th

, 2014   

on the harmonisation of the laws of the 

Member States relating to the making 

available

 

on the 

market of electrical equipment designed for 

use within certain voltage limits. /

Journal of Laws EC  

L96  of 29.03.2014

/

 

The appliance meets the requirements included in:

 

  2009/125/EC (ErP)

 

Directive 

of the European Parliament and of the Council of October 21

th

2009 

establishing a framework

 for the 

setting of ecodesign requirements

 for energy-related pro-

ducts / 

Journal of Laws L 285 of 31.10.2009

 

  327/2011

 (

EU

Regulation 

of March 30

th

, 2011 on implementing the 

2009/125/EC Directive

 

 

of the European Parliament and of the Council 

with regard to ecodesign requirements

 for fans 

driven by motors with an electric input power between

  

125W and 500 kW  / 

Journal of Laws L  

No. 90  of 06.04.2011

 /

 

 

Additionally, the appliance meets following harmonized standard: 
● 

EN ISO-12100:2012 

 
 

 

“Safety of 

machinery

  

– 

Basic concepts, general

 principles  

 

 

 

for design.  Risk assessment and risk reduction” 

● 

EN 60204-1:2018-12

 

 
 

 

“Safety 

of machinery

  

 Electrical equipment of machines.  

 

 

 

Part 1:  General requirements”. 

● 

EN 60034-1:2011 

 
 

 

“Rotating electrical machines  –  Part 1:  Rating data and  

 

 

 

pa

rameters” 

● 

EN ISO 5802:2008/A1:2015-07

 

 
 

 

“Industrial Fans – Performance testing in situ of installing”  

● 

EN ISO 13857:2010 

 
 

 

“Safety 

of

 machinery

 

  

  Safe distances 

to

 prevent hazard  

 

 

 

zones being reached by upper and lower limbs” 

 
 
 

 

2.

 

Application 

WPA-CHEM

 chemically resistant stationary fans  have been constructed  for conveying the air,  

contaminated  with chemically aggressive media  (see Table, pages 9-12)  of maximum dusti- 
ness 0,3 g/m

3

  and  

maximum temperature up to 40ºC.  On demand, are available fans of ma-

ximum 

temperature of the forwarded air: up to +60ºC. 

These fans cannot convey explosive mixtures

.  They are designed for general ventilation of 

rooms  and are applied in ventilation systems  in industry,  agriculture,  building construction, as  
well as  in public facilities such as:  laboratories, store houses, hospitals, schools, canteens,  
swimming pools, sewage treatment plants, etc. 
The fans carry hygienic certificates  issued by National Institute of Public Health  of the Depart-
ment of Communal Hygiene.

 

 

Содержание 802W06

Страница 1: ...al Use 7 8 Troubleshooting Guide 7 9 Maintenance 7 10 Occupational Health and Safety 8 11 Transport and Storage 8 12 Terms of warranty 8 13 Table of resistance of PVC against various substances 9 14 Sample of the Declaration of Conformity 13 802W06 WPA CHEM 160 3000 04 06 2019 EN 802W07 WPA CHEM 200 3000 04 06 2019 EN 802W08 WPA CHEM 250 1500 04 06 2019 EN 802W09 WPA CHEM 300 1500 04 06 2019 EN 80...

Страница 2: ...uirements for energy related pro ducts Journal of Laws L 285 of 31 10 2009 327 2011 EU Regulation of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Additionally the appliance meets followi...

Страница 3: ...or conveying the air containing viscous impurities that could ac cumulate on the device surface especially on the impeller H During operation the maximum impeller rotations should not exceed the nominal rotations I Producer is not responsible for wounds injuries body laceration experienced by User or per sonnel during the improper operational use 4 Technical Data Table No 1 Type of the fan Synchro...

Страница 4: ...an D a b h RD 0 F C G E L H B WPA CHEM 160 3000 160 162 118 263 188 202 150 218 385 501 310 WPA CHEM 200 3000 200 237 133 326 224 240 370 278 510 568 381 WPA CHEM 250 1500 250 297 166 398 280 297 405 308 545 698 473 WPA CHEM 300 1500 300 356 199 482 336 358 440 414 620 848 557 WPA CHEM 400 1000 400 474 265 617 447 470 580 514 680 1080 728 WPA CHEM 500 1000 500 500 315 715 500 570 640 640 730 1235 ...

Страница 5: ...d construction of two parallel walls strengthened with ribs Between the walls is located a spiral element of the housing The housing is made of plates of non plasticised polyvinylchloride To the housing disk is welded an inlet confusor The housing disk is fastened disconnectably at the front wall of the housing its easy dismantling provides free access to the impeller The inlet confusor is also ex...

Страница 6: ...ed during the transport The hole pattern of the foundation ought to be strictly according to the distribution of suitable holes in the fan base Additionally the holes placement of the inlet and outlet should be suitable with adequate holes of the ventilation ducts The fan must be placed strictly horizon tally if the device is not levelled use washers to obtain appropriate positioning Moreover it i...

Страница 7: ...8 Troubleshooting Guide Table No 3 Problem Possible reason Corrective action 1 Significant and sudden decre Obstacle objects reducing the air Clean the ventilation ducts ase of the intake air occurs flow got stack at the inlet grill 2 Sudden vibrations of the fan Obstacle objects reducing the air Disconnect the fan from are occurring flow got stack within the impeller the power supply system and r...

Страница 8: ...essarily after disconnection from the power supply system isolating switch 11 Transport and Storage For the transport time the fan should be protected against damage indentation crack etc Smaller fans can be forwarded in cardboard packages whereas the larger ones should be placed on a pallet protected with foil Use special transporting lines ropes attached at the pallet base or at the fan base in ...

Страница 9: ...l butyl alcohol 100 o Liquid chlorine 100 Dry gaseous chlorine 100 Potassium chlorate 7 3 o Sodium chlorate aqueous solution 25 Ammonium chloride aqueous solution all Zinc chloride Ethylene chloride 100 Methyl chloride 100 Potassium chloride aqueous solution saturated Sodium chloride domestic salt aqueous solution saturated Sodium chloride aqueous solution 5 Chlorobenzene 100 Cadmium cyanide Coppe...

Страница 10: ...Acetic acid icy 100 o Acetic acid aqueous solution 50 Oleic acid 100 o Sulphuric acid 3 50 96 o Sulphuric acid 50 10 Hydrochloric acid 35 Stearic acid 100 Oxalic acid saturated Acidic sodium carbonate aqueous solution saturated Acidic sodium sulphate aqueous solution saturated Nail lacquer o Lysol White liquor 12 5 of the active chlorine o Potassium lye 10 50 Potassium permanganate aqueous solutio...

Страница 11: ...da Vapours of tio urea Vapours of aliphatic hydrocarbons Gaseous ozone Automotive fuel normal petrol Automotive fuel petrol super Automotive fuel diesel oil Paraffin 100 Beer Brake fluid Anti freeze fluid di ethylene glycol Sodium hypochlorite aqueous solution 5 Liquid propane 100 Cresol solution Soap solution saturated Mercury 100 Rum 40 Potassium sulphate aqueous solution saturated Sodium sulpha...

Страница 12: ...ium carbonate aqueous solution saturated Sodium carbonate aqueous solution saturated Water 100 Chlorinated water saturated Aqua regia nitro hydrochloric acid Seawater Sodium hydroxide 50 Sodium hydroxide caustic soda 100 resistant conditionally resistant with the occurrence hazard of tensioning stress cracks 0 conditionally resistant low resistant not resistant ...

Страница 13: ...ments for energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input po wer between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 The appliance meets following harmonized sta...

Страница 14: ...14 CHEM PROOF STATIONARY FAN WPA CHEM 04 06 2019 NOTES ...

Страница 15: ...15 04 06 2019 CHEM PROOF STATIONARY FAN WPA CHEM NOTES ...

Страница 16: ...16 CHEM PROOF STATIONARY FAN WPA CHEM 04 06 2019 NOTES ...

Отзывы: