background image

                                   16 

                                              

cyclone separator

  STORM-H

-{

1000

;

 2000

;

 5000

}

                

 

       

05.11.2019

 

   

 

 
 

NOTES

Содержание 802O14

Страница 1: ...3 40 802O14 STORM 1000 SOFT H 05 11 2019 EN e mail klimawent klimawent com pl 802O15 STORM 2000 SOFT H 05 11 2019 EN www klimawent com pl 802O16 STORM 5000 SOFT H 05 11 2019 EN Contents 1 Introductory...

Страница 2: ...ropean Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Addition...

Страница 3: ...maximum impeller rotations should not exceed nominal rotations I In the course of operational use pay attention that any ignition sources i e glowing cigarettebutts embers should not get into cyclone...

Страница 4: ...4 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 SOFT H STORM 2000 H...

Страница 5: ...5 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 2000 SOFT H STORM 5000 H...

Страница 6: ...version STORM SOFT H 6 sound absorbing set for version STORM H on separate order 7 motor protective switch for versions STORM 1000 H STORM 2000 H or motor starter for version STORM 5000 H The dust se...

Страница 7: ...7 05 11 2019 cyclone separator STORM H 1000 2000 5000 Fig No 1 STORM H and STORM SOFT H Structure...

Страница 8: ...8 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 H STORM 2000 H STORM 5000 H Fig No 2 STORM H Dimensions...

Страница 9: ...9 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 1000SOFT H STORM 2000 SOFT H STORM 5000 SOFT H Fig No 3 STORM SOFT H Dimensions...

Страница 10: ...industrial rooms They can be also used outside the building but with additional protection against atmospheric factors weather conditions i e roofing The separator must be placed stably on the even fl...

Страница 11: ...tion where the cyclone separator serves as a final filter the fan outlet ought to be equipped with a sound absorbing set delivery on separate order Whereas when the cyclone works as a pre filter it is...

Страница 12: ...itoring When the waste container is filled up switch off the device and empty the container according to the instructions on pages 12 14 Having cleaned the con tainer put it underneath the cyclone sep...

Страница 13: ...aded over filled see Fig No 7 9 Maintenance The construction provides long lasting and efficient work without routing technical supervision In the course of operational use simply it is sufficient to...

Страница 14: ...ventilation 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User...

Страница 15: ...of October 21th 2009 establishing a framework for the setting of ecodesign requirements for energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on imp...

Страница 16: ...16 cyclone separator STORM H 1000 2000 5000 05 11 2019 NOTES...

Отзывы: