9
17.10.2019
filtering unit
MATRIX-1000-W
The dust accumulated in the container, placed under the filter (in the lower part of the filtration
chamber). The container has to be emptied periodically.
In order to do this, remove the cover
along with the lance (open the 4 clasps). Subsequently, pull out the filter (see Phot. No.5).
In case of automatically controlled device
MATRIX-1000-W-A
, first take off the coil of the ele-
ctromagnetic valve with the cable and then open the clasp fasteners.
In order to do this, unscrew the nut and take off the
electro-valve from the bolt (Phot No.4).
CAUTION
:
Do not remove the electromagnetic valve while the
power supply is connected, because the electroma-
gnetic valve would burn out.
Necessarily, the cover can be taken off exclusi-
vely after
disconnection from the power supply
.
Photo No.4
Photo No.5
– Withdrawal of the cartridge filter
Having removed the filter, it is important to cover the opening of the dust container with a plug
(connected to the container with a hook and loop fasteners). Otherwise the dust would get out
of the container.