5
17.10.2019
filtering unit
MATRIX-1000-W
In the filtering unit is installed a pressure control
(pressostat) that activates the
signalling lamp
– indicating the need of filter regeneration
, (in case of manual control),
or indicating the neces-
sity of filter replacement, in case of automatic control.
Under the filter is located a fabric container, collecting the dusts dropping from the filter, after
regeneration.
6.
Assembly and Start-up
MATRIX-1000-W requires connection
to the
external compressed
air installation of
pressure at
least 0,6 MPa. The pressure hose ought to be of 16 mm diameter. The appliance is energi-
zed with 230V power through a 5 metres long supply cable with a plug.
Prior to operational use, it is important to check the completeness of device and to put it near
the workplace.
Subsequently, set the hood
of the ERGO
extraction
arm in distance 20
– 30 cm
from the emission of contamination. The appliance is started by a switch, installed on the side
wall of the control chamber.
In the standard version the fan is operated immediately after the device is switched on, where-
as, in the automatic version, the fan starts in 3 seconds
(at the same time
the filter is regenera-
ted). The outline (placement) of the control elements is illustrate in Fig. No.3, 4.