Страница 1: ...ALL MOUNTED SPLIT TYPE AIR CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 Models KSWT009 C H113 SERVICE MANUAL KSWT012 C H113 KSWT018 C H213 KSWT024 C H21...

Страница 2: ...appliance may result in personal injury and property damage The manufacturer or seller cannot be responsible for the interpretation of this information nor can it assume any liability in connection w...

Страница 3: ...Remote control 6 2 5 3 7 1 Air Conditioner Service Manual Operation Details Remote Control The remote control is not preset as Cooling Only Air Conditioner or Heat Pump by the manufacturer Each time a...

Страница 4: ...Air Conditioner Service Manual REMOTE CONTROL GYKQ 05...

Страница 5: ......

Страница 6: ...2 min More than 2 min More than 2 min More than 2 min Indoor Fan Set Speed Set Speed Set Speed Set Speed Set Speed Compressor ON OFF ON OFF ON Outdoor Fan ON OFF ON OFF ON z During the heating operat...

Страница 7: ......

Страница 8: ...oor Fan 9 Fan motor control 1 Rotational frequency feedback control The indoor fan motor is equipped with a rotational frequency sensor and outputssignal to the microprocessor to feedback the rotation...

Страница 9: ...ositioning is decided as follows z When the ON OFF button is pressed z When the vane control is change from AUTO to MANUAL z When the SWING is finished z When the test run starts z When the power supp...

Страница 10: ...pressed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGENCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When...

Страница 11: ...nal of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again z When the indoor fan motorfails the co...

Страница 12: ...5 594 4972 Fax 305 675 2212 www klimaire com sales klimaire com 2190 NW 89 Place Doral FL 33172 USA The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2010 Klimaire Product...