background image

KSIB018-H2161

KSIB024-H2161

Содержание KSIB018-H2161

Страница 1: ...KSIB018 H2161 KSIB024 H2161...

Страница 2: ......

Страница 3: ...atment is necessary Thank you for choosing Klimaire air conditioner please read this owner s manual carefully before operating the unit and keep it carefully for consulation The products in this manua...

Страница 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 6: ...changer when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Air conditioner absorbs heat from outdoor and transmits...

Страница 7: ...outdoor temperature for cooling unit is 10 48 for cooling and heating unit is 15 48 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdo...

Страница 8: ...the actual product Names and functions of each part Indoor unit Air out Outdoor unit Wireless remote control Air in Remote control Front panel Filter Guide louver Wall pipe Bind tape Drainage pipe Rec...

Страница 9: ...by 1 When press button the setting temp will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Operation of remote control Swing up and...

Страница 10: ...button once again to quit it press this key once again to fix the time NOTE This Remote control is universal it could be used formany units some buttons of this control which are not available to this...

Страница 11: ...able In sleep mode setting temperature is adjusted automatically NOTE This remote control is universal it could be used formany units some buttons of this control which are not available to this unit...

Страница 12: ...SLEEP button set the sleep mode 2 Press TIMER button then press button to set the 3 Press light button to control displayer light on or off 4 Press Blow button to set Blow function on or off 5 Press...

Страница 13: ...control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Sketch map for changing batteries NOTE Fig 1 Fig 2 About lock About AU...

Страница 14: ...ight off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this si...

Страница 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Страница 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Страница 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 19: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Страница 20: ...contained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance Indoor Unit Installation Position Selection The air inlet and outlet ve...

Страница 21: ...National Criterion 4 The user power must offer the reliable earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places th...

Страница 22: ...e Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of the space necessary for correct ins...

Страница 23: ...a circle the included angle between the evaporator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws Where is pre covered with plas...

Страница 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Страница 25: ...be fixec by the screw Otherwise it can cause a fire or short circuit caused by water or dust 3 4 5 1 2 Disassemble the handle on the outdoor unit right side plate Take off cord anchorage Connect and f...

Страница 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Страница 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...