38
40149
Current transformer ratio
(CTR)
32 bit integer
R / W
If the password
protection is enabled,
you should enter
a password in the
“Settings Protection”
address.”
40151
Voltage transformer ratio
(VTR)
float
R / W
40153
Demand Duration
32 bit integer
R / W
40155
Password activation
32 bit integer
R / W
40157
Password activation
duration
32 bit integer
R / W
40159
Password value
32 bit integer
R / W
40161
Baud Rate
32 bit integer
R / W
40163
Slave ID
32 bit integer
R / W
40165
Parity control
32 bit integer
R / W
40167
RESERVE
32 bit integer
R / W
40169
RESERVE
32 bit integer
R / W
40171
RESERVE
32 bit integer
R / W
40173
RESERVE
32 bit integer
R / W
40175
RESERVE
32 bit integer
R / W
40177
RESERVE
32 bit integer
R / W
40179
RESERVE
32 bit integer
R / W
40181
RESERVE
32 bit integer
R / W
40183
Menu Browsing On/Off
32 bit integer
R / W
40185
Menu screening duration
32 bit integer
R / W
40187
Homepage Setting
32 bit integer
R / W
40189
Display Backlight Options
32 bit integer
R / W
40191
Display Backlight On Time
32 bit integer
R / W
40193
Voltage Alarm Upper Limit
float
R / W
40195
Voltage Alarm Lower Limit
float
R / W
40197
Voltage Alarm Hysteresis
float
R / W
40199
Voltage Alarm Delay Time
32 bit integer
R / W
40201
Current Alarm Upper Limit
float
R / W
40203
Current Alarm Lower Limit
float
R / W
40205
Current Alarm Hysteresis
float
R / W
40207
Current Alarm Delay Time
32 bit integer
R / W
SECTION 4 RS485 COMMUNICATION
Содержание POWYS 1012
Страница 1: ...1 USER MANUAL Energy Analyzer...
Страница 4: ...4 SECTION 1 GENERAL INFORMATION Enerji Analiz r...
Страница 14: ...14 SECTION 2 INSTALLATION Energy Analyzer...
Страница 17: ...17 SECTION 2 INSTALLATION 2 4 Dimensions mm Fig 2 3 Dimensions...
Страница 18: ...18 SECTION 3 MENUS Energy Analyzer...
Страница 34: ...34 SECTION 4 RS485 COMMUNICATION Energy Analyzer...
Страница 42: ...42 SECTION 5 FACTORY PREVALUES AND SETT NG RANGES Energy Analyzer...
Страница 47: ...47 SECTION 6 TECHNICAL SPECIFICATIONS Energy Analyzer...