Instruction  

Manual

For Professionals...Since 1857

®

ENGLISH

MM6000

•  TRUE RMS

•  BACKLIT DISPLAY

•  BAR GRAPH

•  LEAD STORAGE

•  MAX / MIN

•  3-5/6 DIGIT  

6000 COUNT LCD

•  AUTO / MANUAL 

RANGE

•  AUTO HOLD

HOLD

Apo AUTO

RANGE

TRMS

A-HOLD

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

-

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

%

Duty Cycle Mode

Frequency Mode

V

Voltage Measurement

A

Current in Amps

Ω

Resistance in Ohms

Diode Test

F

Capacitance in Farads

Continuity Test

Relative / Zero Mode

n

Nano 10

-9

µ

Micro 10

-6

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

°F

Degrees Fahrenheit

°C

Degrees Celsius

A-  HOLD 

Auto-Hold Active

LOW 

Z

Low Impedance

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

600mV ˜ 600V

0.1mV ˜ 0.1V

± (0.2% + 5 digits)

1000V

1V

± (0.5% + 10 digits)

Overload Protection:

 1000V   

Input Impedance (Nominal)

: >10M

Ω

, <100pF

Input Impedance (LOW Z)

: >3k

Ω

, <200pF, up to 600V RMS

AC Voltage Measurement

Range

Resolution

Accuracy 

40Hz ~ 400Hz

Accuracy 

400Hz ~ 2kHz

600mV

0.1mV

± (0.75% + 5 digits)

± (2.5% +10 digits)

6V ~ 600V

1mV ~ 0.1V 

± (2.0% + 8 digits)

1000V

1V

± (0.75% + 8 digits)

± (2.0% +8 digits)*

Continued on next page.

Overload Protection:

 1000V RMS 

Input Impedance (Nominal)

:

 >10M

Ω

, <100pF 

Input Impedance (LOW Z)

: >3k

Ω

, <200pF, up to 600V RMS

Frequency Response:

 40 to 2kHz

 

Response:

 True RMS

*Accuracy for 400Hz ~ 1kHz range only.

DC Current Measurement

Range

Resolution

Accuracy

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.0% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (1.5% + 5 digits)

Overload Protection: µAmA: 

400mA (F440mA/1000V fuse) /

 A Input: 

10A

 (

F11A/1000V fuse)

AC Current Measurement

Range

Resolution

Accuracy 

40Hz ~ 2kHz

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.2% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (1.8% + 5 digits)

Overload Protection: µAmA: 

400mA (F440mA/1000V fuse) /

 A Input: 

10A

 (

F11A/1000V fuse)

Frequency:

 40 to 2kHz 

 

Response:

 True RMS

Resistance Measurement

Range

Resolution

Accuracy

600

Ω

 ˜ 6M

Ω

0.1

Ω

 ˜ 0.001M

Ω

 

± (1.0% + 5 digits)

50M

Ω

0.01M

Ω

± (1.5% + 10 digits)

Overload Protection:

 600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

60nF

0.01nF

± (3.5% + 6 digits)

600nF ~ 6000µF

0.1nF ~ 1µF

Overload Protection: 

600V RMS

Frequency Measurement

Range

Resolution

Accuracy

99.99Hz ˜ 399.9kHz

0.01Hz ˜ 0.1kHz

± (0.1% + 3 digits)

Overload Protection:

 600V RMS 

Sensitivity:

 2.5V RMS

Duty Cycle Measurement

Range

Resolution

Accuracy

1.0 ˜ 99.0%

0.1%

± (0.2% per kHz + 0.1% + 8 digits)

Overload Protection:

 600V RMS 

Sensitivity: < 50V RMS

Frequency Range:

 0.5Hz to 10kHz

Diode Test

Overload Protection

Range

Test Current

Open Circuit Voltage

600V RMS

6.0V DC

0.25mA

< 1.8V DC

Continuity Test

Overload Protection

Open Circuit Voltage

Threshold (Appx.)

600V RMS

< 0.44V

<40

Ω

Temperature Measurement

Range

Resolution

Accuracy

-58 ~ 600°F

0.1°F

± (1.0% + 5.4°F)

-50 ~ 600°C

0.1°C

± (1.0% + 3.0°C)

600 ~ 1832°F

1°F

± (1.0% + 5.4°F)

600 ~ 1000°C

1°C

± (1.0% + 3.0°C)

Overload Protection:

 600V RMS 

K-type 

Thermocouple Accuracy:

 Not specified

Specifications subject to change.

WARRANTY

See www.kleintools.com, contact Klein Tools at 1-877-775-5346, or visit a 
distributor for warranty information.

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using  
a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period 
of time. Do not expose to high temperatures or humidity. After a period of 
storage in extreme conditions exceeding the limits mentioned in the General 
Specifications section, allow the instrument to return to normal operating 
conditions before using it.

DISPOSAL / RECYCLE

Caution: 

This symbol indicates that equipment and its accessories 

shall be subject to a separate collection and correct disposal.

CUSTOMER SERVICE

 

  DO NOT apply voltage to thermocouple.

• 

Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000° C).

8. 

Temperature: 

Features:  

MAX/MIN

REL

HOLD

Testing Fuse: 

• 

When selecting uA or mA/A functions the meter will indicate 

LEAd

” if the test leads are not properly connected to the meter. 

• 

Note: This message remaining on the screen after properly 

connecting the test leads is an indication that the fuse is open.

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

1-877-775-5346

www.kleintools.com

Rev A 1/13 

139750

7. 

Frequency (Hz) / Duty Cycle: <400kHz

Features:  

HOLD

6. 

Low Impedance (LOW Z): < 600V 

 

  DO NOT use (LOW Z) mode at voltages greater than 600V.  

• 

Press SELECT to choose AC or DC Voltage.

• 

Use Low Impedance (LOW Z) mode to reduce ghost voltages.

• 

See AC/DC Voltage instruction. 

 

Capacitance Features:  

HOLD

 

 Safely discharge capacitor before   

     measurement.

• 

Reading may take up to 60 seconds 

for large capacitors.

AUTO HOLD

4007036