Klein Tools 69400 Скачать руководство пользователя страница 1

EN

GLISH 

 

Line Splitter (69400) 

 
Instruction Manual 
 

The Klein Tools 69400 Line Splitter separates the hot from the neutral and 
ground wires on a standard 120V outlet so that current measurements can be 
made with a current clamp. Without the Line Splitter, the current clamp 
measures the load current going in both directions, effectively cancelling the 
measurement. The Line Splitter has a standard measurement section and a 
ten-times multiplier section for use with less accurate or higher ranged clamp 
meters. The line splitter can also be used to make voltage checks with 
standard multimeter probes. 

 
 
MEASURING LINE CURRENT 

1. Plug the Line Splitter 

into a standard 120V AC grounded receptacle. 

2. Plug the load’s power cord 

into the Line Splitter. 

3. Place the jaws of the current clamp 

around the X1 or X10 opening of the 

Line Splitter. Turn on the load so it is drawing power. 

4. Read the current measurement 

directly if clamped around the X1 

opening. Divide the reading by 10 if clamped around the X10 opening. 

 

 

 
 
MEASURING LINE VOLTAGE 

1. Plug the Line Splitter 

into a standard 120V AC grounded receptacle. 

2. Plug the load’s power cord 

into the Line Splitter (Optional). 

3. Insert the multimeter leads 

into the Line Splitter terminals marked “VOLT 

CHECK”. 

4. Read the voltage measurement 

on the multimeter. 

Отзывы: