Disassembling and Reassembling the Sonar Head Unit
4-5
7.
Using the 4-mm hex
key, remove the twelve
M5 x 20 mm socket head
cap screws that secure each
of the two transducers to
the frame.
8.
Separate the two halves of
the fairing, along with the
transducers, from the frame
and set them alongside each
other such that the
connectors on the sonar
electronics housing
connector end cap can be
easily accessed.
Figure 4-4:
Removing the Socket Head Cap
Screws that Secure the Transducers to the Frame
Transducer (2)
Figure 4-5:
Fairing Halves Separated from the
Frame
Connector
end cap