background image

1

TEST PROGRAM FOR DISHWASHER MODEL

DW21

CODES

CONTROLS

01

Filling

02

Draining

03

Heating

04

NTC (Thermistor)

05

Flow-meter

06

Turbidimeter

07

Leakage

 

IMPORTANT INFORMATION

 

The change from one step to the next is performed by pressing the 

START

 button. It is

therefore possible to skip one or more steps (except those where level control is
necessary).

 

It is possible to disconnect the appliance during test, in order to check the faulty circuit,
and then to connect it again and continue the test.

 

To cancel the test, the 

START

 button must be kept pressed down for more than 2

seconds.

 

ACCESS TO TEST PROGRAM

Press 

START

 5 times within 5 seconds.

All LED’s around program selector button will light alternately, and all segments of display will
be lit.

 

TO CHECK PROGRAM SELECTOR

Press 

START

 button, the left 2 digits on display indicate ‘01’. Turn the program selector and

check that only 1 LED lights up at a time.

 

CHECK OF BUTTONS

Pressing the buttons makes the related symbol on the display come on or go off. Rotate the

DELAYED END

 button for checking the related symbol.

Note. Pressing the 

START

 button causes the test program to go to the next step.

 

TO CHECK THERMISTOR (NTC) AND TURBIDIMETER

Press 

START

 button, the left 2 digits will indicate ‘02’. After 3 seconds, if a fault exists either

fault code will be displayed in the right 3 digits.

‘d04’

Thermistor fault (valve out of range)

‘d06’

Turbidimeter fault (valve out of range)

Note. If no faults, the 

NORMAL

 and 

INTENSIVE

 LED’s will light.