Page 28 of 72
Errors in master
Parking spaces
Code
Error description
1010
Emergency stop not OK
1020
Unit motor protection has tripped
1030
Gate motor protection has tripped
1040
At least one error has occurred in a sub-distributor
1050
Light barriers test unsuccessful
1060
Current relays test unsuccessful
1500
Corridor cannot be created, check 4th rotary switch
1510
Maintenance switch activated during parking process
1600
Runtime exceeded during parking process
Item
Description
1
Display of the customer numbers stored for the parking spaces, radio numbers, IR
numbers and Bluetooth numbers.
2
Button to change to the previous grid.
3
Button to change to the next grid.
4
Button to change to the previous row.
5
Button to change to the next row.
6
Direct selection of the row and the grid for which the parking spaces are to be shown.
7
Display of the configured max. rows and grids for the parking system and the remote
offset.
The remote offset is required where there are multiple systems within one building.
1
2
6
3
4
7
5
Содержание trendvario6X00