Page 26 of 72
Error code list
General errors
UF errors
GF errors
Basement errors
Code
Error description
0
No error in sub-distributor
10
Emergency stop not OK
20
Release for movement missing
Code
Error description
100
Runtime Lift UF exceeded
101
Runtime Lower UF exceeded
110
Runtime UF open left locking exceeded during lowering
111
Runtime UF open right locking exceeded during lowering
120
Locking UF left opened in idle mode
121
Locking UF right opened in idle mode
140
Inclination UF transverse axis not OK (X)
150
Inclination UF longitudinal axis not OK (Y)
160
Both UF limit switches at upper and lower positions are activated at the same time
170
UF upper position limit switch is not released within 2.5 secs
180
UF bottom limit switch is not released within 2.5 secs
Code
Error description
200
Runtime GF left movement exceeded
201
Runtime GF right movement exceeded
210
Motor protection GF not OK
Code
Error description
300
Runtime Lift basement exceeded
301
Runtime Lower basement exceeded
310
Runtime basement open left locking exceeded during lowering
311
Runtime basement open right locking exceeded during lowering
320
Locking basement left opened while grid was in idle mode
321
Locking basement right opened while grid was in idle mode
340
Inclination UF transverse axis not OK (X)
350
Inclination UF longitudinal axis not OK (Y)
Содержание trendvario6X00