iwitec  Confidential  Documentation                                                                                                                              5 

 

3.1.4.

 

Downlink Setting Command 

Downlink setting command is sent by server to LAS-603 for changing period of temperature report and 

detection. Once LAS-603 getting a downlink command, it should send back a status report for confirmation. 

 

 
 
 

 

 

TX Period 

(1 Byte) 

Detection Period 

(1 Byte) 

Lowest Allowable   

Temp. (2 Bytes) 

Setting 

Command 

FPort: 201 

Temperature: Signed integer, big-endian, multiplies 10. 
                        EX: 0x00 0xEC 

 23.6

°

Highest Allowable   

Temp. (2 Bytes) 

TX Period: Unsigned integer presents period of temperature report in hour, can be 1 to 24. 

Detection Period: Unsigned integer presents period of temperature detection in minute, can be 1 to 30. 

Содержание Lora Alliance Member LAS-603V1

Страница 1: ...taifatech Confidential Documentation LAS 603V1 LAS 603V2 User Manual V 1 0 1...

Страница 2: ...kiwitec Confidential Documentation History Date Version Revision Description Writer 2019 03 31 V 1 0 0 First release LiuKen 2019 05 08 V 1 0 1 Add a note to set downlink window to RX2 LiuKen...

Страница 3: ...Table of Contents 1 Introduction 1 2 Installation 2 3 Report and Data Format 3 3 1 Data Format 4 3 1 1 Temperature Report 4 3 1 2 Status Report 4 3 1 3 Temperature Alarm 4 3 1 4 Downlink Setting Comma...

Страница 4: ...bottom side of LAS 603 for easily mounting on metal surface Figure 1 LAS 603 Figure 2 Magnets at Bottom of LAS 603 Technical Characteristics Power Operating Voltage DC 3V Battery CR AG Battery 2400mAh...

Страница 5: ...he back cover as Figure 3 Then make sure the battery is connected to connector and power switch is ON position Figure 3 Installation of LAS 603 LAS 603 has two mounting methods As shown on Figure 4 ma...

Страница 6: ...d compare read value with allowable temperature range If read temperature is out of allowable temperature range an alarm will be sent Besides the allowable temperature range can be set by downlink com...

Страница 7: ...f allowable range Temperature 2 Bytes Temperature Alarm FPort 202 Temperature Signed integer big endian multiplies 10 EX 0x00 0xEC 23 6 C TX Period 1 Byte Detection Period 1 Byte Lowest Allowable Temp...

Страница 8: ...end back a status report for confirmation TX Period 1 Byte Detection Period 1 Byte Lowest Allowable Temp 2 Bytes Setting Command FPort 201 Temperature Signed integer big endian multiplies 10 EX 0x00 0...

Страница 9: ...er Figure 6 Gateway Setting Setting of LoRaWAN Network Server Final step is create a node on network server as Figure 7 shows The Device EUI Application EUI and Application Key is get from above opera...

Страница 10: ...kiwitec Confidential Documentation 7 Temperature Report The temperature report is under application of LAS603 as following figure shows Figure 8 LAS 603 Report...

Страница 11: ...ick Get Ver Cfg button If the version name does not appear there might be problems on connection between PC and LAS 603 Figure 9 Setup COM Port and Connection Next step is clicking Select Image to cho...

Страница 12: ...tallation If this equipment causes harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interf...

Страница 13: ...contact with hazardous substances may cause bodily harm to the user or people nearby Do not handle the unit remove batteries or cables with wet hands Do not drop or expose the unit to a strong impact...

Страница 14: ...ater leakage Areas subject to condensation or wet areas Areas exposed to excessive vibration Areas exposed to excessive smoke dust or dirt CAUTION Notices about Sensors Do not connect any sensor to th...