Kiwi LAS-604V3 Скачать руководство пользователя страница 17

 

k

iwitec  Confidential  Documentation                                                                                                                              14 

 

6.

 

Certification 

FCC warning   

 

Federal Communications Commission Statement   

This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:   

• This device may not cause harmful interference.   

• This device must accept any interference received, including interference that may cause undesired operation.   

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of 

the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 

radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment causes harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by doing one or more of the following 

measures:   

• Reorient or relocate the receiving antenna.   

• Increase the separation between the equipment and receiver.   

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   

• Consult the dealer or an experienced radio/TV technician for help.   

FCC Caution   

Any changes or modifications not expressly approved by the party responsible for compliance could void the user‘s 

authority to operate the equipment.   

The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter.   

Radiation Exposure Statement:   

This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for 

this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-

located or operating in conjunction with any other antenna or transmitter. 

 

 

 

 

Содержание LAS-604V3

Страница 1: ...taifatech Confidential Documentation LAS 604V3 User Manual V 1 0 0...

Страница 2: ...kiwitec Confidential Documentation History Date Version Revision Description Writer 2019 08 12 V 1 0 0 First release Liu Ken 2020 01 06 V1 0 1 Add Certification and safety information Lin Eden...

Страница 3: ...ion 2 3 Device Setup 4 4 Report and Data Format 7 4 1 Mode A 7 4 1 1 Temperature Report 8 4 1 2 Status Report 8 4 1 3 Temperature Alarm 8 4 1 4 Downlink Setting Command 8 4 2 Mode B 10 4 2 1 Temperatu...

Страница 4: ...date time for synchronous from server at boot up which make sure the accuracy of report time period Technical Characteristics Power Operating Voltage DC 3V Battery Type CR AG Battery 2400mAh x 2 Radi...

Страница 5: ...use LAS 604V3 is installing battery LAS 604V3 can be opened by simultaneously holding and pressing two places in red circle of following figure A battery holder is inside LAS 604V3 as Figure 2 The su...

Страница 6: ...which is used to wakeup LAS 604V3 when it enters deep sleep mode Figure 3 Wakeup Button There is a jumper inside LAS 604V3 for selecting operation mode of LAS 604V3 Figure 4 is an example which sets...

Страница 7: ...vation and LoRaWAN Class should be set to ABP and Class A separately Note Due to LAS 602 4 sending periodically report at each clock the downlink window is recommended to set to RX2 for preventing fro...

Страница 8: ...kiwitec Confidential Documentation 5...

Страница 9: ...kiwitec Confidential Documentation 6 Temperature Report in Platform The temperature report is under application of LAS 602 4 as following figure shows Figure 7 LAS 602 4 Report...

Страница 10: ...d status report a LoRaWAN MAC command DeviceTimeReq is sent from LAS 604V3 to server for time synchronization Figure 8 depicts the entire sequence from power on Figure 8 LAS 604V3 Sequence Diagram The...

Страница 11: ...tting a downlink command it should send back a status report for confirmation Battery 1 Byte Temperature 2 Bytes Temperature 2 Bytes Temperature Report FPort 200 Battery The most significant bit indic...

Страница 12: ...Bytes Setting Command FPort 201 Temperature Signed integer big endian multiplies 10 Highest Allowable Temp 2 Bytes TX Period Unsigned integer presents period of temperature report in hour can be 1 to...

Страница 13: ...t depends on how many temperature records in a single report Temperature report record amount and total payload bytes for different mode are shown below Mode Report Interval Measure Period Record Amou...

Страница 14: ...for setting The Downlink Payload rules and examples are shown below Figure 9 LAS 604V3 Downlink Page Setting Command OP Code Operation Payload Range 0x01 Manually Offset Setting 100 100 0xFF9C 0x0064...

Страница 15: ...ort number and click Get Ver Cfg button If the version name does not appear there might be problems on connection between PC and LAS 604V3 Figure 10 Setup COM Port and Connection Next step is clicking...

Страница 16: ...kiwitec Confidential Documentation 13 Figure 12 Firmware Upgrade Success...

Страница 17: ...equipment causes harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by doing on...

Страница 18: ...injury or damage to persons or things DANGER To Prevent Serious Accidents Do not disassemble repair or modify the unit and or accessories Do not use the unit in any environment that is exposed to che...

Страница 19: ...by Kiwi technology Inc Do not put anything on top of the cable or the unit This may cause overheating Make sure that sensor and cable plugs are all inserted fully so as not to cause an improper connec...

Страница 20: ...lean cloth Make sure to remove dust and dirt from plugs of any cables Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss Please note that this docume...

Страница 21: ...n Do not use the sensor on the human body Temperature Humidity Sensor If extremely severe temperature changes occur it may result in large errors in humidity measurement Once the sensor s temperature...

Отзывы: