background image

10

2.

Use 

³⁄₈

" nut driver to connect the neutral (white) wire to the 

center terminal block post with one of the 10-32 hex nuts.

3.

Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.

4.

Securely tighten hex nuts.

NOTE:

 For power supply cord replacement, only use a power 

cord rated at 250 volts minimum, 40 amps or 50 amps that is 
marked for use with nominal 1

³⁄₈

" (3.5 cm) diameter 

connection opening, with ring terminals and marked for use 
with ranges.

5.

Replace terminal block access cover.

6.

Slide range back so rear range foot is under the anti-tip 
bracket. See the “Verify Anti-Tip Bracket is Installed and 
Engaged” section.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or 
circuit breaker box. Depending on your electrical supply, make 
the required 3-wire or 4-wire connection.

1.

Strip outer covering back 3" (7.6 cm) to expose wires. Strip 
the insulation back 1" (2.5 cm) from the end of each wire.

2.

Allow enough slack in the wire to easily attach to the wiring 
terminal block.

3.

Complete electrical connection according to your type of 
electrical supply (4-wire or 3-wire connection).

4-wire Connection: Direct Wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes 

Recreational vehicles

In an area where local codes prohibit grounding through the 
neutral

1.

Part of metal ground strap must be cut out and removed.

2.

Use Phillips screwdriver to remove the ground-link screw 
from the back of the range. Save the ground-link screw and 
the end of the ground link under the screw.

3.

Pull the conduit through the strain relief on cord/conduit plate 
on bottom of range. Allow enough slack to easily attach 
wiring to the terminal block.

A. 10-32 hex nut
B. Line 1 (black)

C. Ground-link screw

D. Neutral (white) wire

E. Line 2 (red)

A

B

C

D

E

3"

(7.6 cm)

1"

(2.5 cm)

A. Metal ground strap
B. Discard

C. Ground-link screw

A. Terminal block
B. Ground-link screw

C. Cord/conduit plate
D. Line 2 (red) wire

E. Neutral (white) wire

F. Line 1 (black) wire

G. Bare (green) ground wire

A

B

C

A

B

C

D

E

F

G

Содержание YKFED500ESS

Страница 1: ...ed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual ...

Страница 2: ...racket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damage This range has been designed in accordance with the requirements of UL and CSA In...

Страница 3: ...NOTE 24 61 0 cm minimum when bottom of wood or metal cabinet is covered by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 35 90 8 cm 0 3 cm cooktop heig...

Страница 4: ...num cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range The wiring diagram is located on...

Страница 5: ... may be done with the range on its back or with the range supported on 2 legs after the range has been placed back to a standing position NOTE To place range back up into a standing position put a sheet of cardboard or hardboard in front of range Using 2 or more people stand range back up onto the cardboard or hardboard 2 Adjust the leveling legs to the correct height Leveling legs can be loosened...

Страница 6: ...spond to the bracket holes of the determined mounting method See the following illustrations 5 Using two 12 x 1 Phillips head screws provided mount anti tip bracket to the wall or floor A Anti tip bracket B Mark edge of range C 2 4 cm WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so ...

Страница 7: ...e cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block Tighten strain relief screw against the power supply cord Power Supply Cord Direct Wire WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrica...

Страница 8: ...nstallation following instructions for your type of electrical connection 4 wire recommended 3 wire if 4 wire is not available Electrical Connection Options A Removable retaining nut B Strain relief A B If your home has And you will be connecting to Go to Section 4 wire receptacle NEMA type 14 50R A UL listed 250 volt minimum 40 amp range power supply cord 4 wire connection Power supply cord 4 wir...

Страница 9: ...lock posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 8 Replace terminal block access cover 9 Slide range back so rear range foot is under the anti tip bracket See ...

Страница 10: ... insulation back 1 2 5 cm from the end of each wire 2 Allow enough slack in the wire to easily attach to the wiring terminal block 3 Complete electrical connection according to your type of electrical supply 4 wire or 3 wire connection 4 wire Connection Direct Wire Use this method for New branch circuit installations 1996 NEC Mobile homes Recreational vehicles In an area where local codes prohibit...

Страница 11: ... if local codes permit connecting ground conductor to neutral supply wire 1 Pull the conduit through the hole and conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 2 Attach terminal lugs to line 1 black bare green ground and line 2 red wires Loosen do not remove the setscrew on the front of the terminal lug and insert exposed wire end through bot...

Страница 12: ...for contact information 6 Repeat steps 1 and 2 to ensure that the range foot is engaged in the anti tip bracket If the rear of the range lifts more than 1 3 cm off the floor without resistance the anti tip bracket may not be installed correctly Do not operate the range without anti tip bracket installed and engaged Please reference the Assistance or Service section of the Use and Care Guide or the...

Страница 13: ...r maintenance 4 Slide range back so rear range foot is under anti tip bracket 5 Refer to the Verify Anti Tip Bracket Is Installed and Engaged section to verify engagement 6 Check that range is level 7 Reconnect power WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is...

Страница 14: ...14 Notes ...

Страница 15: ...15 Notes ...

Страница 16: ...W10694065A 2014 All rights reserved 9 14 Printed in U S A ...