background image

Содержание KHMS2050SBL1

Страница 1: ...ate to Wall 8 Prepare Upper Cabinet 8 Installthe Microwave Oven 9 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 MICROWAVE HOOD COMBINATION SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert ...

Страница 2: ...t 3 7 6 cm of clearance between the wall and the microwave oven so that the door can open fully Some cabinet and building materials are not designed to withstand the heat produced by the microwave oven for cooking Check with your builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damages For gas cooktop we recommend that combined cooking ...

Страница 3: ...elay fuse or time delay circuit breaker A separate circuit serving only this microwave oven GROUNDING iNSTRUCTiONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current The microwave oven is equipped with a cord having a grounding wire with a...

Страница 4: ...oven is being handled i g i a _ The microwave oven is set for recirculation installation For wail or roof venting changes must be made to the venting system See Venting Design Specifications section NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or ...

Страница 5: ... screen Wall Venting Installation Only To Remove Wall Damper Vent Cover 1 Locate the wall damper vent cover on the back of the microwave oven 2 Using diagonal wire cutting pliers gently snip out the damper vent cover at the perforations A B C D A Mounting screw B Damper assembly C Long tab inside slot Roof Venting Installation Only To Remove Roof Damper Vent Cover 1 Locate the roof damper vent cov...

Страница 6: ...ns show examples of preferred installation configurations with the mounting plate No Wall Studs at Corner Holes Figure 1 No Wall Studs at Corner Holes Figure 2 B D i i i i i i E F NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done g _ Wall Stud at One Corner Hole Figure 3 i Ii i i i i i I i I i i i...

Страница 7: ...4 10 2 cm from the mark made in Step 6 and mark Using a straightedge draw the 2 horizontal level lines through the marks made in steps 6 and 8 Draw the 2 vertical plumb lines down from the marks made in Step 7 to complete the 12 x 4 30 5 x 10 2 cm rectangle This is the venting cutout area Cut a 3 4 19 mm hole in one corner of the cutout area Using a keyhole saw cut out the venting cutout area In a...

Страница 8: ...d at One Corner Hole in the Drill Holes in Rear Wall section 2 Start a toggle nut on the bolt from the back of the mounting plate Leave enough space for the toggle nut to go through the wall and to open 3 Position mounting plate on the wall making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet 4 Push the bolt with toggle nut through the drywall and fing...

Страница 9: ... closed and taped shut 3 Using 2 or more people lift microwave oven and hang it on support tabs at the bottom of mounting plate NOTE To avoid damage to the microwave oven do not grip or use the door or door handle while the microwave oven is being handled 5 Rotate microwave oven up toward upper cabinet NOTE If venting through the wall make sure the damper assembly fits easily into the vent in the ...

Страница 10: ...Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock 2 Plug microwave oven into grounded 3 prong outlet 3 Reconnect power 4 Check the operation of microwave oven by placing 1 cup 250 mL of water on the turntable and programming a cook time of 1 minute at 100 power Test vent fan and exhaust by...

Страница 11: ...g compound to seal exterior wall or roof opening around cap not installing 2 elbows together for optimal hood performance If venting through the wall be sure that there is proper clearance within the wall for the damper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the ...

Страница 12: ... round a rectangular to round transition piece must be used In addition a rectangular 3 7 6 cm extension vent between the damper assembly and rectangular to round transition piece must be installed to keep the damper from sticking ASSISTANCE Call your authorized dealer or service center When you call you will need the microwave oven model number and serial number Both numbers can be found on the m...

Отзывы: