Gas supply

requirements

Electrical

requirements

WARNING

Observe all governing codes and
ordinances.
Important: Cooktop must be connected
to a regulated gas supply.

A.

This installation must conform with

local codes and ordinances. In the
absence of local codes, installations must
conform with American National
Standard, National Fuel Gas Code ANSI
Z223.1 — latest edition** or CANI —
B149.1 or 2**.

D.

Provide a gas supply line of 3/4" 

rigid pipe to the cooktop location. A
smaller size pipe on long runs may result
in insufficient gas supply. Pipe-joint
compounds, suitable for use with L.P. gas,
must be used. With L.P. gas, piping or
tubing size can be 1/2" minimum. L.P. gas
suppliers usually determine the size and
materials used on the system.

E.

If local codes permit, a new AGA or

CSA design-certified, 4-5 foot (1.2-1.5 m)
long, 1/2" or 3/4" I.D., flexible metal
appliance connector is recommended for
connecting this cooktop to the gas supply
line. Do Not kink or damage the flexible
connector when moving the cooktop. The
pressure regulator has 3/8" female pipe
threads. You will need to determine the
fittings required, depending on the size of
your gas supply line, flexible metal
connector and shutoff valve.

F.

The supply line shall be equipped

with an approved shutoff valve. This valve
should be located in the same room as
the cooktop and should be in a location
that allows ease of opening and closing.
Do Not block access to the shutoff valve.
The valve is for turning on or shutting off
gas to the appliance.

to cooktop

shutoff valve
“open” position

gas supply
line

G.

If rigid pipe

is used as a gas 
supply line, a combination of pipe
fittings must be used to obtain an in-line
connection to the cooktop. All strains
must be removed from the supply and
fuel lines so cooktop will be level and in
line.

H.

The regulator must be checked at

a minimum 1-inch (2.5 cm) water column
above the set pressure. The inlet pressure
to the regulator should be as follows for
operation and checking the regulator
setting:

NATURAL GAS:
Set pressure 4 inches (10.2 cm).
Supply pressure 7-14 inches (17.8 cm
to 35.5 cm) maximum.

L.P. GAS:
Minimum pressure 10 inches (25.4 cm).
Supply pressure 14 inches (35.5 cm).

I.

Line pressure testing:

Testing above 1/2 psi (3.5 kPa) 
(14 inches (35.6 cm)) W.C. (gauge)
The cooktop and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures
greater than 1/2 psig (3.5kPa).

Testing below 1/2 psi (3.5 kPa) 
(14 inches (35.6 cm)) W.C. (gauge) or
lower
The cooktop must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3.5 kPa).

Electrical Shock Hazard

Plug into a grounded 3-prong
outlet.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these
instructions can result in death,
fire, or electrical shock.

WARNING

A 120-volt, 60-Hz, AC-only, 15-ampere,
fused electrical supply is required. A
time-delay fuse or circuit breaker is
recommended. It is recommended that a
separate circuit serving only this
appliance be provided.

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Check with a qualified electrician if
you are not sure whether the cooktop
is properly grounded.

Do Not ground to a gas pipe.

Explosion Hazard

Use a new AGA or CSA approved
gas supply line.

Install a shut-off valve.

Securely tighten all gas
connections.

If connected to LP, have a
qualified person make sure gas
pressure does not exceed 14"
water column.

Examples of a qualified person
include licensed heating
personnel, authorized gas
company personnel, and
authorized service personnel.

Failure to do so can result in
death, explosion, or fire.

4

B.

Input ratings shown on the

model/serial rating plate are for elevations
up to 2,000 feet (610 m). For elevations
above 2,000 feet (610 m), ratings are
reduced at a rate of 4% for each 1,000
feet (305 m) above sea level.

C.

The cooktop is equipped for use

with NATURAL gas. It is design-certified
by CSA International for NATURAL and
L.P. gases with appropriate conversion.
The model/serial rating plate, located on
the underside of the burner box, has
information on the type of gas that can be
used. If this information does not agree
with the type of gas available, check with
the local gas supplier. See Page 2 for L.P.
gas conversion instructions.

Содержание KGCS105GSS - 30 Inch Sealed Burner Gas Cooktop

Страница 1: ...own the model and serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the underside of the cooktop burner box Model ___________________________ Serial ___________________________ IMPORTANT Read and save these instructions Gas Built in Cooktops 30 76 2 cm 36 91 4 cm 43 109 2 cm 15 38 1 cm 30 76 2 cm 21 53 3 cm 2 7 8 7 3 cm 21 53 3 cm 2 7 8 7 3 cm 2 ...

Страница 2: ...n does not meet the minimum cabinet clearances install a range hood above the cooktop to avoid burn hazards WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do n...

Страница 3: ...atest edition or with local codes NOTE 24 61 cm min clearance if bottom of wood or metal cabinet is protected by not less than 1 4 0 6 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 04 cm stainless steel or 0 024 0 06 cm aluminum or 0 020 0 05 cm copper 30 76 2 cm min clearance between top of cooking platform and bottom of an unprotected wood or metal cabinet...

Страница 4: ...pply pressure 14 inches 35 5 cm I Line pressure testing Testing above 1 2 psi 3 5 kPa 14 inches 35 6 cm W C gauge The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5kPa Testing below 1 2 psi 3 5 kPa 14 inches 35 6 cm W C gauge or lower The cooktop must be isolated ...

Страница 5: ...he standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 3 prong polarized ground type outlet power supply cord 3 prong ground plug ground prong Now start With cooktop in kitchen Numbers correspond to steps 7 15 16 7 6 5 5 1 3 1 Remove foam shipping blo...

Страница 6: ...5 Check operation of the cooktop burners Push in and turn each control knob to LITE position The flame should light within 4 seconds Do Not leave the knob in the LITE position after burner lights If burners do not light properly turn control knob to the OFF position Check that burner cap is in the proper position Check that power supply cord is plugged in and that circuit breaker or house fuse has...

Страница 7: ...service company Contact the dealer from whom you purchased your cooktop or Look in the Yellow Pages of your telephone directory under Appliances Household Major Service and Repair or Call the Consumer Assistance Center The number is listed in your Use and Care Guide When you call you will need The cooktop model number The cooktop serial number Both numbers are listed on the model serial rating pla...

Страница 8: ... IS EQUIPPED WITH A THREE PRONGED GROUNDING PLUG WHICH MATES WITH STANDARD THREE PRONGED GROUNDING WALL RECEPTACLES Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerou...

Страница 9: ...de modèle et de série avant d installer la table de cuisson On trouve ces deux numéros sur la plaque signalétique située en dessous de la caisse de la table de cuisson N de modèle ______________________ N de série ________________________ IMPORTANT Lire et conserver ces instructions Tables de cuisson encastrées à gaz 30 po 76 2 cm 36 po 91 4 cm 43 po 109 2 cm 15 po 38 1 cm 30 po 76 2 cm 21 po 53 3...

Страница 10: ...courants d air comme fenêtres portes et ventilateurs ou bouches de chauffage Ne pas entraver la circulation d air de ventilation et de combustion À l emplacement d installation de la table de cuisson toutes les ouvertures dans les murs ou le plancher doivent être obturées Lors de l installation d une table de cuisson sous des placards existants s il n est pas possible de respecter les distances de...

Страница 11: ... Z240 ou de tout code local en vigueur NOTE Dégagement de séparation d au moins 24 po 61 cm si le fond du placard de bois ou métallique est protégé par une plaque de matériau ignifugé d au moins 1 4 po 0 6 cm recouverte d une tôle d acier de calibre 28 MSG d acier inoxydable de 0 015 po 0 04 cm d aluminium de 0 024 po 0 06 cm ou de cuivre de 0 020 po 0 05 cm Distance de séparation minimale de 30 p...

Страница 12: ...on de l appareil et le contrôle du réglage du détendeur la pression d alimentation doit correspondre aux indications ci dessous GAZ NATUREL Pression de réglage 4 po 10 2 cm Pression d alimentation 7 14 po 17 8 cm à 35 5 cm maximum PROPANE Pression minimum 10 po 25 4 cm Pression d alimentation 14 po 35 5 cm I Test de la pression d alimentation Test à une pression supérieure à 1 2 lb po2 3 5 kPa 14 ...

Страница 13: ... local conformément aux prescriptions de l édition en vigueur de la norme ACNOR C22 1 Code canadien des installations électriques Partie 1 On peut obtenir des exemplaires des normes mentionnées aux adresses suivantes National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 prise bien polarisée à 3 a...

Страница 14: ...uvrer chaque bouton de commande pour le placer à la position LITE La flamme devrait s allumer en moins de 4 secondes Après l allumage du brûleur ne pas laisser le bouton à la position LITE Si un brûleur ne s allume pas correctement ramener le bouton de commande à la position d arrêt OFF Vérifier que le couvercle de brûleur est à la position convenable Vérifier que le cordon d alimentation de l app...

Страница 15: ...près vente agréé Pour obtenir les coordonnées d un établissement agréé de service après vente Contacter le concessionnaire chez qui l appareil a été acheté Chercher dans l annuaire téléphonique Pages jaunes à la rubrique Appareils ménagers Service et réparations ou bien Contacter le centre d assistance aux consommateurs On trouve le numéro de téléphone dans le Guide d utilisation et d entretien Lo...

Страница 16: ...liée à la terre Mise en grade Étiquetter tous les fils avant la déconnexion pour la réparation des commandes Les erreurs de câblage peuvent être la cause d un fonctionnement incorrect et dangereux Mise en grade Étiquetter tous les fils avant la déconnexion pour la réparation des commandes Les erreurs de câblage peuvent être la cause d un fonctionnement incorrect et dangereux Mise en grade Étiquett...

Отзывы: