6
Gas and Electric Connection Locations
Installation Clearances
*
NOTES:
Dimension “B” can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet is protected by not less than
0.25” (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood above the cooktop, follow the hood instructions for dimensional clearances above the cooktop surface.
A
B
C
D
*B min.
C
A
D
E
F
I
J
K
M
G
N
O
H
C
D
E
L
size
model
island trim
A
*B (min.)
backguard
island trim
backguard
backguard
opening
cabinet and
countertop
C
D
E
countertop only
36" (91.4 cm) or
35
⁷⁄₈
" (91.1 cm)
for zero clearance fit
35
¹⁄₄
"
(89.5 cm)
36"
(91.4 cm)
48" (121.9 cm)
49" (124.5 cm)
1
³⁄₄
"
(4.4 cm)
5"
(12.7 cm)
KGCP462K
KGCP463K
KGCP467J
36" (91.4 cm)
48" (121.9 cm)
KGCP482K
KGCP483K
KGCP484K
KGCP487J
6"
(15.2 cm)
5"
(12.7 cm)
5"
(12.7 cm)
6" (15.2 cm)
1
³⁄₄
"
(4.4 cm)
5"
(12.7 cm)
48"
(121.9 cm)
48"
(121.9 cm)
49"
(124.5 cm)
48" (121.9 cm)
48"
(121.9 cm)
47
¹⁄₄
"
(120.0 cm)
48" (121.9 cm) or
47
⁷⁄₈
" (121.6 cm)
for zero clearance fit
A. See chart.
B. See chart.
C. See chart
D. See chart
E. See chart
F. 18" (45.7 cm) min. clearance upper
cabinet to countertop
G.
³⁄₄
" (1.9 cm)
H.
6⁷⁄₈
" (16.1 cm)
I. 4
³⁄₄
" (12.1 cm)
J. 22
¹⁄₄
" (56.5 cm)
K. 2" (5.1 cm)
L. 12
⁵⁄₁₆
" (31.3 cm)
M. 24" (61 cm)
A. 3 prong ground-type outlet should be located on
left hand side of cutout 8" (20.3 cm) max. from
enclosure sidewall
B. 10" (25.4 cm)
C. 14" (35.6 cm)
D. Gas supply line should be located in this area on
rear or side walls, or the supply line can come up
through the floor.
NOTE:
Solid side and bottom of cutout enclosure not